Section 3.1
ATOM
I
NSTALLATION
M
OUNTING
Depending on the configuration, an ATOM can weigh up to 7.3kg (16lbs). When choosing an installation
location, ensure the mounting brackets are capable of supporting the unit weight. Norsat recommends
that the unit is supported using at least eight of the mounting holes on two opposing sides (four holes per
side). The waveguide output port (J4) must not be used to physically support the unit.
Refer to
for the size and position of the ATOM mounting holes.
O
UTDOOR
U
SE
The ATOM is designed for use in an outdoor environment and is sealed to prevent water ingress. Ensure
the waveguide and/or feed connected to J4 are also sealed with gaskets to prevent water ingress.
Section 3.2
F
ANS
&
B
ASEPLATE
C
OOLING
The standard ATOM configuration employs an integrated radiator and IP55 fans to cool the unit. A
minimum clearance of 1 inch must be maintained around the air intake and exhaust during use. The fans
are a field replaceable assembly; contact Norsat for details on replacement kits. If the unit is deployed
inside a radome, ensure there is adequate cooling to remove heat and prevent the unit from overheating.
The ATOM is also available with a flat plate in place of the radiators and fans. It is the
user’s
responsibility to ensure that the plate the unit is mounted to is capable of rejecting any heat produced by
the unit. Please contact Norsat for cooling requirement specifications.