ATOM Ku GaN 20-40-80W BUC &
SSPA
052910
33
052910_rA - Operator Manual for ATOM Ku
GaN Series 20-40-80W
Chapter 3
Misc. Info
Section 3.1
ATOM
I
NSTALLATION
M
OUNTING
Depending on the configuration, an ATOM Ku GaN can weigh up to 2.30kg (5.06lbs). When choosing an
installation location, ensure the mounting brackets are capable of supporting the unit weight. Norsat
recommends that the unit is supported using at least four of the mounting holes on two opposing sides
(four holes per side). The waveguide output port (J5) must not be used to physically support the unit.
for the size and position of the ATOM mounting holes.
O
UTDOOR
U
SE
The ATOM is designed for use in an outdoor environment and is sealed to prevent water ingress. Ensure
the waveguide and/or feed connected to J5 are also sealed with gaskets to prevent water ingress.
Section 3.2
F
ANS
&
B
ASEPLATE
C
OOLING
The standard ATOM configuration employs an integrated radiator and IP55 fans to cool the unit. A
minimum clearance of 1 inch must be maintained around the air intake and exhaust during use. The fans
are a field replaceable assembly; contact Norsat for details on replacement kits. If the unit is deployed
inside a radome, ensure there is adequate cooling to remove heat and prevent the unit from overheating.
The ATOM is also available with a flat base
in place of the radiators and fans. It is the user’s
responsibility to ensure that the external cooling plate that the unit is mounted to is capable of rejecting
any heat produced by the unit. Please contact Norsat for cooling requirement specifications.