ATOM Ku GaN 20-40-80W BUC &
SSPA
052910
22
052910_rA - Operator Manual for ATOM Ku
GaN Series 20-40-80W
and Reset Point. By default, Over Temperature fault is automatically cleared when the System Temperature
drops below the device’s Temperature Reset Point.
There are no comparable commands to clear PLL and Power faults, as they are not manually resettable
because they reflect hardware conditions. The device automatically clears these faults when the hardware
conditions change.
setmute
This command sets the software mute state of the unit. If the command code is 1 , the amplifier will be
muted. If the command code is 0, the amplifier mute will be controlled as shown in Section
The mute state can be monitored by examining the MUTE code in the “getfaults” message.
Figure 2-16: Command setmute - mute unit
Figure 2-17: Command setmute - unmute unit
C
OMMAND
R
ESPONSE
The CLI operates on a command response format. Each time a command is entered, a response will be
displayed. If a command executed correctly, an “ok” along with potential parameters and values will be
displayed. Otherwise, “err” will be displayed along with a description of the error.
The potential errors that may be displayed are:
•
Invalid Command
– The command was not recognized
•
Invalid Parameter
– The parameter was not recognized
•
Invalid Value
– The value was invalid for the command/parameter
•
Missing Parameter
– A required parameter was not provided
Each command response will have the following format:
<CR><LF><msg><CR><LF>
where msg is as described above and in the command summary and example tables below. Note that a
response is enveloped by leading and trailing <CR><LF> characters. <CR> denotes a Carriage Return
character, and <LF> denotes a Line Feed character.