ATOM Ku GaN 20-40-80W BUC &
SSPA
052910
32
052910_rA - Operator Manual for ATOM Ku
GaN Series 20-40-80W
Section 2.11
F
AULT
I
NDICATOR
/
LED
D
ESCRIPTION OF
O
PERATION
Norsat Ku GaN 20W, 40W and 80W are equipped in a general purpose Status LED signal. This signal is
intended to give a visual aid of the status of the device.
M
ODES OF
O
PERATION
The Status LED in the Front Panel of the devices will show three different statuses:
STARTING, FAULT,
and NO FAULTS.
S
TARTING WITH
N
O
F
AULTS
S
TATUS
The Status LED will flash once for a lapse of approximately one second every time the power of the device
in recycled to OFF and set back to ON. If no fault is detected in the device at the Power Up, the led will g o
to OFF afterwards settling in that state.
F
AULT AND
N
O
F
AULTS
In the event of a
PLL Fault,
an
Over Input Fault,
a
Power Fault,
or an
Over Temperature Fault
, the
Status LED will turn on independently of whether the MUTE STATE of the device is UNMUTED or
MUTED due Hardware or Software. If the cause of the fault disappears the Status LED will turn OFF until
any of the Faults shows again independently of the MUTE STATE.
Commented [WP5]:
Update to Ku GaN