System Troubleshooting
PROBLEM
TROUBLESHOTING STEPS
Can’t connect to the
ODU web interface
1. Verify that the ODU power connector is properly seated and threaded.
2. Verify that the Ethernet connector is connected and locked at both
ends.
3. On a computer attached to the RSW network, open command line and
ping the IP address (default is 192.168.77.30).
a. if the IP address is reachable, try loading the web page using
Firefox.
4. If the system includes the optional IDU, check the ODU IP settings in
the network settings page and confirm that you are accessing the
correct address.
5. Disconnect and reconnect the Ethernet connection on the client side.
6. Power cycle the ODU.
7. Use an IP Scanner to search the network for the devices MAC
address.
8. If the IP address has been lost, a hardware factory reset may be
required (see Section 3.9.3).
9. If the problem persists, contact Norsat customer support.
System Power Fault is
present
1. If the LNBs are being powered by the on-board ULC, open the ODU
Web Interface and confirm that the ULC is enabled.
2. If the LNBs are being powered by an external source, ensure that
power is being applied to the system.
3. If the ULC is enabled, disable the ULC and then enable the ULC.
4. Power cycle the ODU.
5. If the problem persists, contact Norsat customer support.
One of the LNBs is
not receiving power
1. Verify that the ODU power connector is properly seated and threaded.
2. Check that the LNB connectors are properly threaded at the ODU.
3. If the LNBs are being powered by the on-board ULC, open the ODU
Web Interface and confirm that the ULC is enabled.
4. If the LNBs are being powered by an external source, ensure that
power is being applied to the system.