18
4.2 Settings / Sector limits / Sweep / Home
The searchlight movements can be limited by setting a sector for horizontal and vertical
movements.
The settings will have the same function as a mechanical stop unless for the reset/init-
tializing routine.
Do not exceed -180 and 180 degrees.
Do not set the limit lower than the sweep sector.
Main menu / Settings / Hardware Installation / Searchlight limits
Main menu/ Searchlight limits /
1. Start sweep horizontal, this is the same button as in main menu
Set the min/max sweep degrees in pop-up menu
2. Start sweep vertical, can be operated at the same time as for horizontal
Set the min/max sweep degrees in pop-up menu
3. Home position 1, same as button in main menu
Set the position for horizontal and vertical parking in pop-up menu
4. Home position 2
Set the position for horizontal and vertical parking in pop-up menu
1
3
2
4
Min and max degrees/position is limited by sector limits, described above.