INSTALLATION-
INSERTHEATERSONLY
WARNING:ThisapplianceandflueMUSTbeinstalledinafullmasonryfireplace,andmustbe
installedbyaqualifiedwoodheaterinstalleraccordingtothelatestversionofAS2918.
FireplaceConstruction
Thiswoodheater
beinstalledinafull
must
masonry
fireplace,which
non-combustible
has been carefully inspected for cracks or
deterioration. The chimney should be
cleanedpriortoinstallation
You
installafluetheentirelengthofthe
must
chimney.Thiswillhelpyourheaterperformto
itsfullcapabilities.Itisalsoeasiertoclean.
HearthConstruction
The diagram below shows the minimum
dimensions (in millimetres) for the hearth.
The hearth shall consist of no less than 45
mm thick compressed fibre cement sheet,
with thermal conductivity not greater than
0.33W/m°K.
Donotbuildthehearthoverthefrontofthe
heaterasthiswillpreventaccesstothefan
throughthefrontbottomairinletcover.
6
590
980
Dimensions(inmillimetres)
GLI
F
E
D
C
B
A
firebox
height
facia
width
f
acia
height
flueto
rear
firebox
width
firebox
depth
600
980
700
152
690
460
ClearancestoCombustibles
The diagram below shows the minimum
clearances (in millimetres) to combustible
materials.
There must be not less than 1150 mm
betweenthetopofthehearthtotheunderside
of the combustible mantlepiece. This is
equivalent to 450 mm above the top of the
heaterfascia.
Thecombustiblesurroundcolumnsmustbe
notlessthan1075mmapart.
1150
1075
450