background image

1

Marcello

 

Wood-Burning Soapstone Stove

Installation, and Operating Manual

INSTALLER:  Leave this manual with the party 

responsible for use and operation.

OWNER: Save this manual for future reference. 

Do not discard!

QUESTIONS: Call your Authorized Dealer.

If this solid fuel room heater is not properly 

installed, assembled and used, a house 

fire may result. For your safety, follow 

the installation directions. Contact local 

building or fire officials about restrictions 

and installation inspection requirements in 

your area.

Please read this entire manual before 

installation and use of this wood-burning 

room heater. Failure to follow these 

instructions could result in property 

damage, bodily injury, or even death. 

1.  Do not store or use gasoline or other 

flammable vapors and liquids in the 

vicinity of this or any other appliance. 

2.  Do not overfire - If any external part 

starts to glow, you are overfiring. Close 

air controls. Overfiring will void your 

warranty. 

3.  Comply with all minimum clearances to 

combustibles as specified. 

WARNING

SAFETY NOTICE

Tested and approved to use with dry, seasoned 
wood only. Do not burn wet or green wood. 
Burning any other type of fuel may be a danger 
and will void your warranty.

CAUTION

Summary of Contents for Marcello

Page 1: ... in your area Please read this entire manual before installation and use of this wood burning room heater Failure to follow these instructions could result in property damage bodily injury or even death 1 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance 2 Do not overfire If any external part starts to glow you are overfiring Close ai...

Page 2: ...TY DAMAGE BODILY INJURY OR LOSS OF LIFE CONTACT THE LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA WHEN NOT ADDRESSED IN THIS MANUAL OR BY LOCAL CODE AUTHORITIES INSTALLATION SPECIFICATIONS AND REQUIREMENTS DEFER TO NFPA 211 OR CSA B 365 DO NOT CONNECT THIS Stove TO ANY AIR DISTRIBUTION DUCT OR SYSTEM EXTREMELY HOT WHILE IN OPERATION KEEP ...

Page 3: ...U S guidelines established by UL 1777 the National Fire Protection Association s Code NFPA 211 Standards for Chimneys Stoves Vents and Solid Fuel Burning Appliances or similar regulations may apply to the installation of a solid fuel burning appliance in your area For further information on using your heater safely obtain a copy of the NFPA publication Using Coal and Wood Stoves Safely NFPA No HS ...

Page 4: ... cm x 30 cm A round fireclay liner must have a minimum inside diameter of 6 15 cm and maximum inside diameter of 8 20 cm A larger chimney should be relined with an appropriate code approved liner Brick or modular block must be a minimum of 4 10 cm nominal thickness Stone construction must be at least 12 30 cm thick A newly built chimney must conform to local codes or in their absence must comply w...

Page 5: ...local building inspector or authority having jurisdiction to determine what regulations apply and what permits may be required before installation of a solid fuel burning appliance Notify your insurance company before installing this stove INSTALLATION NORSK KLEBER REQUIRES ALL INSTALLATION AND ASSEMBLY OF THIS STOVE TO BE PERFORMED BY TRAINED PROFESSIONALS Chimney Requirements There are two types...

Page 6: ...HT Listed Stainless Steel Chimney Chimney Connector Adaptor Fig 5 Connection to prefabricated chimney Chimney Connector Requirements Use 6 single wall or Listed 6 double wall stovepipe to connect the stove to the chimney Single wall stovepipe must be black steel or stainless steel and have a mini mum thickness of 24 gauge Do not use aluminum or galvanized steel pipe for chimney connection these ma...

Page 7: ... carry that laboratory s testing mark Be sure to follow all of the manufacturer s instructions Fig 7 Floor protection dimensions A B C D E U S 36 47 in 8 in 35 in 16 in 2 in 926 mm 203 mm 889 mm 406 mm 51 mm CAN 35 75 in 8 in 45 in 18 in 2 in 908 mm 203 mm 1143 mm 457 mm 51 mm In the U S The National Fire Protection Association s publication NFPA 211 Standard for Chimneys Stoves Vents and Solid Fu...

Page 8: ...led to conform to the clearances in Fig 9 Wall Mounted Protection When reducing clearances through the use of wall mounted protection For the U S refer to NFPA 211 Standard for Chimneys Stoves Vents and Solid Fuel Burning Appliances for acceptable materials proper sizing and construction guidelines For Canada refer to CAN CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment a...

Page 9: ...llo pillars for burn plate tall 0 2 2 01 28 18 Marcello rear stone 1 2 3 01 28 25 Marcello top plate for exit front part 1 1 1 01 28 26 Marcello top pltae for exit rear part 1 1 1 01 80 30 Black door Marcello 1 1 1 Part components in own box 01 00 75 Product documentation 1 1 1 01 00 89 Sealing cord for burn plate 160 cm 1 1 1 01 00 90 Installation instructions 1 1 1 01 00 91 Thin steel sheets rod...

Page 10: ...Marcello 140 Exploded View ...

Page 11: ...e very heavy We recommend that you first sort the stones by size and shape A repair kit is included for small repairs to the stones Glue must not be used for assembly Suggested tools for assembly Plastic or wooden mallet Multi tip screwdriver Utility knife Work gloves Papertowel Handle the stones carefully Soapstone can be easily chipped or damaged if not handled correctly ...

Page 12: ... rear It must also extend 2 in 51 mm to both sides under a horizontal chimney con nector section This results in a floor protector 38 in x 45 in 95 cm x 114 cm See Fig 3 Fig 3 Floor protection dimensions A B C D E U S 38 in 8 in 37 in 16 in 2 in 950 mm 200 mm 940 mm 400 mm 51 mm CAN 38 in 8 in 45 in 18 in 2 in 950 mm 200 mm 1140 mm 460 mm 51 mm DANGER Failure to locate the stove the minimum distan...

Page 13: ...ring Base plate 1 Put in place the 30 mm 2 part steel ring assembly with a recess for the door 2 Insert 6 200 mm metal sealing strips into the vertical tracks between the stones 3 Place two supports for the fire plate next to the side stones and so that they are resting on base plate 4 Place the fire plate down onto supports with the countersinking for the sealing cord facing upwards 5 Install fix...

Page 14: ... track as shown 2 Insert the 6 200 mm metal strips into the vertical slots between the stones 1 Put in place section 2 rear stone 2 side stones front stone and 2 corner stones 2 Put in place the 2 part 30mm steel ring assembly with a recess for the door 3 Insert 6 metal sealing strips into the vertical slots between the stones 4 Place two support blocks for the fire plate next to the side stones a...

Page 15: ...ion above it and then seal that section following the same procedure There after follow the same procedure for each section above the burn chamber Sealing the joints Step 6 Step 7 1 Disassemble the cover for the draft adjustment Use the enclosed 3 mm Allen key 2 Put in place the movable draft adjustment plate with the draft adjustment handle 3 Fit the cover in front of the draft adjustment Draft a...

Page 16: ...s between the stones 4 Insert the 4 8 mm steel dowels into the bottom holes of the side stones 5 Apply apply fire sealant see step 7 8 1 Put in place the smoke direction plate with the opening at the rear Smoke direction plate 8 mm steel dowels Step 10 Step11 1 Place the two part Skamol bottom down onto the soap stone plate in the bottom with the recess for the door facing down 2 Put in place the ...

Page 17: ...the side stones as shown below 8 Place the smoke direction plate so that it rests on the steel dowels and position it against the rear wall 1 Place the labyrinth blocks as shown below Labryrinth blocks Smoke hood stone 8 mm steel dowels Step 15 Step 16 Step 17 Flue adapter Top plate rear Top plate front 1 Place the rear part of the top plate as shown 2 Place the front part of the top plate as show...

Page 18: ...th indirect supply from wall valves in the outer wall In newer more airtight houses it may be necessary to supply the combustion air directly into the combustion chamber If the combustion air is to be supplied as described above this must be prepared before the stove is mounted to the chimney The supply air duct must be insulated so that condensation does not occur The air supply pipe has a diamet...

Page 19: ...stone stove Adding firewood to a still hot soapstone stove When reloading the stove while a bed of hot embers still exists follow this reloading procedure Never open the door when there is still fire flames in the burn chamber The load has to burn out completely first Always use the stove mitt when tending to the fire A little more about wood Use dry wood with moisture content of less than 17 This...

Page 20: ...rom the firebox Hold the door open just slightly for a couple of seconds before opening it fully This will also help ensure that no smoke escapes into the room Use a stove tool or poker to distribute the hot embers equally around the firebox and push ashes into the ash pan Load the fuel usually with smaller logs first Close the door and secure the latch the wood will start to burn after a few minu...

Page 21: ... thereof that is repaired or replaced during the limited warranty period will be warranted under the terms of the limited war ranty for a period not to exceed the remaining term of the original limited warranty or three 3 months whichever is longer Norsk Kleber and its U S importer Hestia Industries warrant this soapstone stove to be defect free in material and workmanship to the original purchase...

Reviews: