15
Norsonic Nor1218
Instruction Manual
Specifications
Mounting direction
The microphone shall be mounted with the tip pointing
upwards and the axis of symmetry shall be vertical.
The acoustic reference axis for the microphone may
either be horizontal or vertical.
Acoustic performance
General
Sensitivity:
typically 25 mV/Pa (-32 dB re 1V/Pa) –
individually calibrated. (Based on typical open circiut
sensitivity of 50 mV/PA for microphone and typical
6 dB attenuation in the preamplifier.
)
Measurement range:
From noise floor up to at least
140 dB re. 20 µPa (peak).
Self-noise:
A-weighted: < 18 dB re. 20 µPa
Z-weighted: < 22 dB re 20 µPa (22.5 Hz - 22.5 kHz
Frequency response
See Technical description.
Frequency correction is recommended for conform-
ance with the requirements in IEC 61672 for class 1
sound level meters.
Directional response
The directional response satisfies the requirements for
a Class 1 sound level meter according to IEC61672-1.
See section 4.4 Directional response for further infor-
mation.
General
Mounting on a tripod: 3/8” UNC (photo-tripod)
Temperature range:
-10ºC to +50ºC
Satisfies requirements in IEC 61672-1 when operated
with a suitable instrument.
Air pressure:
85 kPa to 108 kPa
Humidity/rain:
Up to 100%, IP55
Height:
375 mm (without tripod adapter)
Diameter:
Approx 78 mm with windshield
Weight:
280 g (without tripod adapter)
Summary of Contents for nor1218
Page 1: ...INSTRUCTION MANUAL Outdoor microphone nor1218 ...
Page 2: ......
Page 3: ...Outdoor microphone nor1218 ...
Page 6: ......