40 Troubleshooting,
Terminal Adapter
trouble
Check the single line telephone connection by using an
installer’s test telephone.
2. Check the connections to the jack.
3. Check the connections to the
4. Disconnect the
and replace it with a working Not-star
telephone. If the telephone still works properly, this verifies
that the KSU is working properly.
5. Verify that programming has been done as described in the
Analog Terminal Adapter Installation Card.
6. If the trouble seems to be in the KSU, double check all wiring
and programming options. If this does not help, refer to the
KSU down
section of Troubleshooting.
WARNING
This unit must be powered from a Class
source
that is UL and CSA Listed.
Auxiliary Ringer trouble
1. If the Auxiliary Ringer is used for Service Modes, ensure that
Service Modes is activated from the Control Telephone.
2. Check the wiring between the Auxiliary Ringer generator and
the ringing device. (See the Internal Wiring chart.)
3. Check the wiring between the Auxiliary Ringer and the
distribution panel.
4. Check the Auxiliary Ringer contact operation with an
ohmmeter across the pins.
5. Check that the Auxiliary Ringer is programmed to ring for
any of the following programmable settings: