10-30
Page 110
2008-10-01
Table 7. SAM-e Tube Matrix (cont)
Table 8. SAM-e Inlet and Adapter Configurations
Part No.
Description
Qty
1503448
TYPE C, 84" (213.4 cm) WIDE
75 lbs/hr (34 kg/hr)
1503449
TYPE C, 90" (228.6 cm) WIDE
75 lbs/hr (34 kg/hr)
1503450
TYPE C, 96" (243.8 cm) WIDE
75 lbs/hr (34 kg/hr)
1503451
TYPE C, 102" (259.1 cm) WIDE
75 lbs/hr (34 kg/hr)
1503452
TYPE C, 108" (274.3 cm) WIDE
75 lbs/hr (34 kg/hr)
1503453
TYPE C, 114" (289.6 cm) WIDE
75 lbs/hr (34 kg/hr)
1503454
TYPE C, 120" (304.8 cm) WIDE
75 lbs/hr (34 kg/hr)
1503455
TYPE C, 126" (320.0 cm) WIDE
75 lbs/hr (34 kg/hr)
1503456
TYPE C, 132" (335.3 cm) WIDE
75 lbs/hr (34 kg/hr)
1503457
TYPE C, 138" (350.5 cm) WIDE
75 lbs/hr (34 kg/hr)
1503458
TYPE C, 144" (365.8 cm) WIDE
75 lbs/hr (34 kg/hr)
NOTE:
Add 6" (15.2 cm) to in-duct height for outside-duct mounting of header.
Part No.
Description
Qty
1503479
Inlet Adapter Kit 1, SAM-e, 100 lbs/hr 1.75"
1503480
Inlet Adapter Kit 2, SAM-e, 200 lbs/hr 2x1.75"
1503481
Inlet Adapter Kit 3, SAM-e, 300 lbs/hr 3x1.75"
1503482
Inlet Adapter Kit 4, SAM-e, 400 lbs/hr 4x1.75"
1503483
Inlet Adapter Kit 5, SAM-e, 500 lbs/hr 5x1.75"
1503484
Inlet Adapter Kit 6, SAM-e, 600 lbs/hr 6x1.75"
1503485
Inlet Adapter Kit 7, SAM-e, 700 lbs/hr 7x1.75"
1503486
Inlet Adapter Kit 8, SAM-e, 800 lbs/hr 8x1.75"
NOTES:
1. Inlet/Adapter: Allows direct connection of the humidifier steam outlets to the SAM-e. Therefore, there is no
adapter located at the humidifier.
2. Consult SAM-e Shop Drawings for more details.
3. All adapters come complete with hose/clamp connections for all outlets.
4. All electrode humidifiers must run individual steam lines directly to SAM-e.
Summary of Contents for NHPC
Page 1: ...2538144 B NH Series NHTC NHPC ELECTRODE STEAM HUMIDIFIER Engineering Manual TM ...
Page 9: ...10 00 Page 1 2008 10 01 10 00 INTRODUCTION ...
Page 10: ...10 00 Page 2 2008 10 01 Figure 1 NHTC ...
Page 13: ...10 00 Page 5 2008 10 01 Figure 2 Optimum Boiling Time Figure 3 Conductivity ...
Page 18: ...10 00 Page 10 2008 10 01 Figure 6 Typical NHRS Installation Sheet 1 of 2 ...
Page 19: ...10 00 Page 11 2008 10 01 Figure 7 Typical NHRS Installation Sheet 2 of 2 ...
Page 20: ...10 10 Page 12 2008 10 01 10 10 HUMIDITY STEAM ABSORPTION AND DISTRIBUTION ...
Page 35: ...10 10 Page 27 2008 10 01 Figure 2 Psychrometric Chart ...
Page 64: ...10 10 Page 56 2008 10 01 Figure 30 NORTEC OnLine Monitoring ...
Page 71: ...10 20 Page 63 2008 10 01 10 20 SPECIFICATIONS ...
Page 81: ...10 30 Page 73 2008 10 01 10 30 SUBMITTALS ...
Page 86: ...10 30 Page 78 2008 10 01 Figure 2 Primary Line Voltage Wiring to Unit ...
Page 87: ...10 30 Page 79 2008 10 01 Figure 3 Physical Data NHTC NHPC 005 030 ...
Page 88: ...10 30 Page 80 2008 10 01 Figure 4 Physical Data NHTC NHPC 050 100 ...
Page 89: ...10 30 Page 81 2008 10 01 Figure 5 Physical Data NHTC NHPC 150 200 ...
Page 96: ...10 30 Page 88 2008 10 01 Figure 12 In Duct AHU Installation With Mounting Frame Installation ...
Page 98: ...10 30 Page 90 2008 10 01 Figure 13 In Duct AHU Installation With Mounting Frame Installation ...
Page 100: ...10 30 Page 92 2008 10 01 Figure 16 Atmospheric SAM e Adapter Dimensions ...
Page 101: ...10 30 Page 93 2008 10 01 Figure 17 Atmospheric Steam Header and Adapter Configuration ...
Page 102: ...10 30 Page 94 2008 10 01 Figure 18 Physical Data for Remote Mounted Blower Pack ...
Page 103: ...10 30 Page 95 2008 10 01 Figure 19 Physical Data Units with Optional Built On Blower Packs ...
Page 104: ...10 30 Page 96 2008 10 01 Figure 20 Physical Data Units with Optional Built On Blower Packs ...