![background image](http://html1.mh-extra.com/html/nortec/rh2/rh2_installation-and-operation-manual_1705822011.webp)
Installation |
8
Mounting with Keyholes
1
The RH2 humidifier is wall mounted using a keyhole located on the back of the unit
cabinetry.
2
Use #8 x 2 in. (5 cm) screws mounted into 2x4 studs or better. 2 screws are needed, one for
hanging the unit and one for securing so it will not lift off the keyhole.
3
Install the top screw so that 1/4 in. (6 mm) is exposed. Raise the unit and place the screw
head through the keyhole.
4
Make sure the unit is level and then insert and tighten the second screw through the bottom
hole. Tighten the top screw. See Figure 5: Mounting With Keyholes.
Figure 5: Mounting With Keyholes
Note:
Use screws longer than 2” (5 cm) if drywall or other spacer is present.
Install Second Screw
after hanging
humidifier
#8 x 2 in. (5 cm)
Wood Screws
Insert screw so that
1/4 in. (6 mm) exposed,
hang unit, tighten
screw.
2x4 or Other
Structural
Member
Keyhole
Hole