MM571W / MM572W Installation Instructions
25
PUSH-TO-OPEN OPERATOR MOUNTING
Level
horiz
ontal
cross
mem
ber
Level o
pener
Gate in Closed Position
Gate Bracket
Post Bracket Assembly
Step 3
Step 4
●
With the gate in the CLOSED
position, use clamps to secure the
operator to the gate post and center
cross member of the gate.
●
Ensure that the operator is level.
●
With the operator arm temporarily
secured to the gate, check to
ensure there is at least 2 inches of
clearance between the operator arm
and gate. (See illustration in Step 4
below).
20” MAX
CLEARANCE DIAGRAM
●
Disconnect the operator arm from the
gate bracket.
●
While supporting the operator, swing
the gate and operator to the OPEN
position.
●
Check for recommended clearances
and binding as shown.
●
Ensure that the necessary arm stroke
does not exceed 20 inches.
●
Make adjustments to the mounting
brackets to achieve the recommended
clearances.
TIP:
Turning the pivot bracket over
gives more hole alignment options for
the gate post pivot bracket assembly.
Your Property
WARNING:
THE OPERATOR MUST BE INSTALLED WHILE FULLY RETRACTED, WITH THE GATE IN THE