2
ADVANCED OPERATION
All On/All Off
The PD300EMZ5-1 supports the ALL ON / ALL OFF commands. The PD300EMZ5-1 can be set
to respond to ALL ON and ALL OFF commands four different ways.
Refer to your Controller for information on how to set the PD300EMZ5-1 to operate in the
manner you desire. Some Controllers may be only able to set certain settings of ALL ON/ALL
OFF response.
The four different ways the PD300EMZ5-1 can be setup to respond to ALL ON and ALL OFF
commands are:
1.
Responds to ALL ON or the ALL OFF command.
2.
Responds to ALL OFF command but will not respond to ALL ON command.
3.
Responds to ALL ON command but will not respond to ALL OFF command.
4.
Responds to ALL ON and the ALL OFF command.
CONFIGURATION
Adjusting Dim Rate
Dim Level
The brightness setting of the Dimmer is called the Dim Level. When the Dim Level is adjusted,
the rate that Dim Level changes depends on the Dim Step (Parameter 7) and Dim Timer
(Parameter 8) values. These values can be changed instantly to allow various scenes and
effects. These values can also vary between local control, remote commands from the hub or
associated device and ALL ON/OFF commands.
Dim Step (remote and local)
Dim Step can be set to a value of 1 to 99. This value indicates how many levels the dimmer
will change each time the Dim Timer expires.
Dim Timer (remote and local)
The Dim Timer (how fast the dim steps happen). It can be set to a value of 1 to 255. This value
indicates in 10 millisecond resolution, how often the dim level will change.
Examples:
• If the Dim Timer parameter value is set to 1, every 10mS the Dim Level will change by the
Dim Step value.
• If the Dim Timer parameter value is set to 255, every 2.55 seconds the Dim Level will change
by the Dim Step value.
With the combination of the two parameter values that control the dim rate, the dimmer can
be adjusted to dim from maximum to minimum or minimum to maximum at various speeds
between 10 millisecond and 252.45 seconds (over 4.25 minutes).
Parameter
Length
Valid
Values
Confi guration Option
7
1 byte
1 – 99
Dim Remote On/Off Step (default = 3, 3 steps)
8
1 byte
1 – 255
Dim Remote On/Off Timer (default = 10, 10 mS)
9
1 byte
1 – 255
Dim Local On/Off Step (default = 10, 10 steps)
10
1 byte
1 - 255
Dim Local On/Off Timer (default = 10, 10 mS)
11
1 byte
1 - 99
Dim ALL On/Off Step (default = 10, 10 steps)
12
1 byte
1 - 255
Dim ALL On/Off Timer (default = 3, 3 mS)
LED Intensity
You can set the intensity of the LED to fi t the environment the PD300EMZ5-1 is being used in
from off to full brightness. This is done by changing Parameter 2.
Parameter
Length
Valid Values
Confi guration Option
2
1 byte
0 - 99
0 = OFF
1 = Very Dim
99 = Full Brightness (default)
Power Monitoring
The PD300EMZ5-1 provides a visual display of the amount of energy being
consumed when the switch is turned on by illuminating the LEDs in one of 5
different colors.
Energy
0 to 2 Watts
White
3 to 60 Watts
Green
60 to 100 Watts
Blue
101 to 200 Watts
Yellow
201 to 300 Watts
Red
The Power Monitoring can be turned off untilizing Parameter 11. When turned off, the
PD300EMZ5-1 will no longer illuminate the LED to indicate any energy use and periodic
reports to the hub on energy use will also be turned off.
Parameter
Length
Valid Values
Confi guration Option
11
1 Byte
0
Power Monitoring OFF
1
Power Monitoring ON
(Default)
The duration the LED will change color to indicate the amount of energy being
used can be set using Parameter 12. After displaying the “energy used” color, the
LED wil revert to OFF or ON (white) as determinded by confi guration parameter #3.
Parameter
Length
Valid Values
Confi guration Option
12
1 Byte
1 - 254
Number of seconds LED
displays power level usage.
Default = 60
255
Power Level usage
continuous ON
The PD300EMZ5-1 supports the Confi guration command.
Each unit can be confi gured to
operate slightly differently than how it works when you fi rst install it.
Using the Confi guration command you can confi gure the following:
Night Light
By default, the LED on the PD300EMZ5-1 will turn OFF when the load attached is turned ON.
To make the LED turn ON when the load attached is turned ON, set Parameter 3 to a value of 1.
Parameter
Length
Valid Values
Confi guration Option
3
1 Byte
0
LED OFF when the load is on, and ON when
the load is off
(default mode)
1
LED ON when the load is on, and OFF when
the load is off
2
LED is always on
3
LED is always off
4
LED blinks during RF transmissions from or
to the device
Over-The-Air (OTA) Update
A Quadruple tap of the switch enables the fi rmware update mode. Firmware update mode
must be entered before the system Controller sends the fi rmware update command to begin
downloading new fi rmware. Firmware update mode is enabled for 60 seconds after the
quadruple tap. If the Firmware update does not begin before the end of the 60 seconds then
fi rmware update mode is exited returns to normal operation. The LED “winks” twice per second
indicating it is in fi rmware update mode.
Resetting to Defaults
Each confi guration Parameter can be set back to its default setting by setting the default bit
in the Confi guration Set command. See your Controller’s instructions on how to do this
(and if it supports it). All confi guration commands will be reset to their default state when the
PD300EMZ5-1 is excluded from the Z-Wave network by using the Controller to reset the node.
SPECIFICATIONS
Power:
120 VAC, 60 Hz
Signal (Frequency):
908.42 MHz / 916 MHz
Maximum Load:
300 W for lamps only 120 VAC
Range: Up to 130 feet line of sight
NOTICES
Z-Wave® and Z-Wave Plus® are registered trademarks of Sigma Designs and its subsidiaries in the United
States and other countries.
Covered by one or more claims of patents: http://sipcollc.com/patent-list/ and http://intusiq.com/patent-list/
Terms and Conditions pertaining to the sale of this Nortek Security & Control wireless mesh network product
are available at http://nortekcontrol.com/terms_conditions.php
REGULATORY INFORMATION
We, Nortek Security & Control, LLC, of 1950 Camino Vida Roble STE 150, Carlsbad, CA 92008, declare
under our sole responsibility that the device PD300EMZ5-1 complies with Part 15 of the Fcc rules.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) This device must accept any interference received,
including interference that may cause undesired operation.
FCC Notice
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
• Consult the dealer or an experienced radio/TV technician to help.
Changes or modifi cations not expressly approved by the party responsible for compliance could void
the user’s authority to operate the equipment
IC Notice
This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Le présent appareil
est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur
de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
This device complies with the Industry Canada license exempt RSS standard(s). Operation is subject to
the following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
WARRANTY
What is Covered?
Nortek Security & Control (“NS&C”) warrants to consumers who purchase this product for personal,
family or household purposes new from NS&C directly or from an authorized NS&C dealer, that the
product will be free from defects in materials and workmanship for a period of (1) year from the date
of purchase. This warranty only applies if the product is installed at a residence in the 50 United
States or District of Columbia, and only at the site of the original installation. It is not transferable. This
warranty is not extended to resellers.
If a defect exists, NS&C will have you ship the defective part or product to us and we will, at our option, either
repair or replace it. This warranty does
not
cover the cost of labor to remove a defective part or product or to
reinstall any repaired or replacement part or product
This warranty does
not
cover defects or damages caused by improper handling, maintenance, storage,
installation, removal or re-installation, misuse, non-factory authorized modifi cation or alteration, use of
incompatible accessories, electrical power problems or surges, impact by foreign objects, accident, fi re, acts
of God, normal wear and tear or shipping damage other than a shipment from NS&C. Note that all NS&C
products are designed to be installed, removed and serviced by trained individuals or professionals.
Keep your original sales receipt as it will be required to obtain warranty service.
This warranty shall not be extended or restarted upon receipt of any repaired or replacement part or product
under this warranty. No person is authorized to extend or otherwise modify this warranty.
How do I Obtain Warranty Service?
To obtain warranty service, email our Returns Department at returns@nortek.com. Include your name,
address, telephone number, the model number of your product, a copy of your original sales receipt, and
a description of the problem. Unless we need to discuss the situation further with you, you will be emailed a
Return Authorization Number and shipping instructions. If we need to discuss the situation further with you,
we will call or email you. NS&C may require troubleshooting on installed product before a Return Authorization
Number is issued. Anything shipped to us without a Return Authorization Number will be automatically returned
unopened. You are responsible for the charges for shipment to us, unless you are a California resident.
Limitations
THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXCEED THE WARRANTY PERIOD PROVIDED HEREIN.
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply
to you.
NS&C SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE
BREACH OF ANY WRITTEN OR IMPLIED WARRANTY.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation
or exclusion may not apply to you.
This warranty gives you specifi c legal rights, and you may also have other legal rights which vary from State
to State.
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,PD300EMZ5-1,GO CONTROL; P/N 10008250 X8 INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 8.500” x 14.000”; TOLERANCE ± .125”; SCALE: 1-1 FOLDING: FOLD PAGE 4 X FINISH WITH LOGO SHOWING;
PAGE 2 OF 2
Copyright © 2015 Nortek Security & Control LLC
10008250 X8