background image

Combustion
Air

Combustion

Air

45° Elbow

(Field Supplied)

Vent

Field Supplied Strap

1" Min. Clearance

Exhaust 

Vent

Figure 5. Side Wall installation

Vent

Vent

8" min.

Combustion

air

Figure 6. Concentric Vent & Combustion-air

roof Terminations

1" maximum

(TYp)

12" minimum clearance

(18” for Canada) or 

maximum expected 

snow level

Vent

8" min.

Vent

Combustion air

Figure 7. Concentric Vent &

Combustion-air Wall Terminations

inSTaller: pleaSe leaVe THeSe inSTruCTionS WiTH THe oWner.

708999C (Replaces 708999B)

procedure 3: multiventing Terminations

When two or more direct vent furnaces are vented near each other, each furnace must be individually vented as 

shown in Figures 6 and 7. NEVER common vent or breach vent this furnace. When two or more direct vent furnaces 

are vented near each other, each vent termination may by installed as shown in Figure 6 and 7. It is important that 

vent terminations be made as shown to avoid recirculation of flue gases. A minimum distance of 8 inches MUST 

be maintained.

Specifications & illustrations subject to change without notice or incurring obligations (07/16).