IMPORTANT SAFETY INFORMATION

INSTALLER: Please read all instructions before servicing 

this equipment. Pay attention to all safety warnings and 

any other special notes highlighted in the manual. Safety 

markings are used frequently throughout this manual to 

designate a degree or level of seriousness and should not 

be ignored. 

WARNING

 indicates a potentially hazardous 

situation that if not avoided, could result in personal injury or 

death. 

CAUTION

 indicates a potentially hazardous situation 

that if not avoided, may result in minor or moderate injury 

or property damage.

 WARNING:

ELECTRICAL SHOCK, FIRE OR

EXPLOSION HAZARD

Failure to follow safety warnings exactly could 

result in serious injury or property damage.
Improper servicing could result in dangerous 

operation, serious injury, death or property 

damage.
Before servicing, disconnect all electrical power 

to furnace.
• Before servicing, disconnect all electrical 

power to the air handler.

•  When servicing controls, label all wires prior 

to disconnecting. Reconnect wires correctly.

•  Verify proper operation after servicing.

 WARNING:

NITROGEN

HEALTH

FLAMMABILITY

REACTIVITY

0 Minimal Hazard

1 Slight Hazard

1

0

0

B64BM Air handlers leave the factory with a 

nitrogen holding charge. Use caution when 

preparing coils for field connections. If repairs 

make it necessary for evacuation and charging, 

it should only be attempted by qualified, 

trained personnel thoroughly familiar with this 

equipment. Some local codes require licensed 

installation service personnel to service this 

type of equipment. Under no circumstances 

should the equipment owner attempt to install 

and/or service this equipment. Failure to comply 

with this warning could result in equipment 

damage, personal injury, or death.

REQUIREMENTS & CODES

 WARNING:

This unit must be installed in accordance 

with instructions outlined in this manual 

during the installation, service, and operation 

of this unit. Unqualified individuals should 

not attempt to interpret these instructions or 

install this equipment. Failure to follow safety 

recommendations could result in possible 

damage to the equipment, serious personal 

injury or death.

•  The installer must comply with all local codes and regulations 

which govern the installation of this type of equipment. 

Local codes and regulations take precedence over any 

recommendations contained in these instructions. Consult 

local building codes for special installation requirements.

• This equipment contains nitrogen gas. Installation or 

servicing should only be performed by qualified trained 

personnel thoroughly familiar with this type equipment.

•  All electrical wiring must be completed in accordance with 

local, state and national codes and regulations and with 

the National Electric Code (ANSI/NFPA 70) or in Canada 

the Canadian Electric Code Part 1 CSA C.22.1.

•  Installation of equipment may require brazing operations. 

Installer must comply with safety codes and wear 

appropriate safety equipment (safety glasses, work gloves, 

fire extinguisher, etc.) when performing brazing operations.

•  Install this unit only in a location and position as specified on 

page 4

 & 

page 5

. This unit is designed only for Indoor 

installations and should be located with consideration of 

minimizing the length of the supply and return ducts. See 

Table 4 

Table 5, (page 16)

 and the rating plate for proper 

circulating airflow data.

•  Follow all precautions in the literature, on tags, and on 

labels provided with the equipment. Read and thoroughly 

understand the instructions provided with the equipment 

prior to performing the installation and operational checkout 

of the equipment.

•  Air handler installations in a residential garage must be 

installed as specified on 

page 6

.

•  This air handler may not be used for temporary heating 

or cooling of buildings or structures under construction. 

Operating the air handler during construction is not 

permitted and will void the manufacturer’s warranty.

Summary of Contents for B64BM Series

Page 1: ...as well Pay attention to all safety warnings and any other special notes highlighted in the manual Improper installation of the furnace or failure to follow safety warnings could result in serious inj...

Page 2: ...10 Control Board 10 Twinning 10 Line Low Voltage Connections 11 Heater Kits 11 Electronic Air Cleaner EAC 11 STARTUP ADJUSTMENTS 11 Before You Start the Unit 11 Air Circulation 11 Running the Blower C...

Page 3: ...s manual during the installation service and operation of this unit Unqualified individuals should not attempt to interpret these instructions or install this equipment Failure to follow safety recomm...

Page 4: ...ent Refer to applicable building codes for details Static pressure drop through louvered openings and through return air plenums should be considered in the overallductdesigninthedeterminationofthetot...

Page 5: ...ance be sure to install all the needed gaskets and grommets around penetrations into the air handler such as for electrical wiring AIR HANDLER INSTALLATION B64 series air handlers are shipped ready fo...

Page 6: ...Right Installations 1 Remove the coil access door Unscrew the line set tube close off plate from the front left cabinet rail 2 Slide the coil and drain pan assembly out of the unit 3 Remove the sheet...

Page 7: ...ult in equipment damage personal injury or death The installer should make every effort to ensure the field installed refrigerant containing components of the system have been installed in accordance...

Page 8: ...htenanadditional1 4turnusingtwowrenches The movement of the two lines will show how much the nut is tightened If a torque wrench is used tighten to 10 12 ft lbs or 14 16 Nm Connecting the Linesets The...

Page 9: ...d tubing or pvc pipe and adequately trapped Both drain tubes must have a minimum diameter of 3 4 and be trapped separately IMPORTANT Failure to install a trap may result in condensation overflowing th...

Page 10: ...plate Use UL listed conduit and conduit connectors for connecting the supply wires to the unit and for proper grounding Field supplied bushings for the power supply cables must be added to support and...

Page 11: ...on is sized properly Verify filter is properly and securely installed IMPORTANT Before starting the unit install the initial charge on units that are factory shipped with a nitrogen holding charge 1 R...

Page 12: ...locations are shown in Figure 11 page 15 If any component of the air handler must be replaced use only factory authorized replacement parts specified in the Replacement Parts List provided online WAR...

Page 13: ...caution when preparing coils for field connections If repairs makeitnecessaryforevacuationandcharging it should only be attempted by qualified trained personnel thoroughly familiar with this equipmen...

Page 14: ...11 4 15 8 17 8 11 4 3 1 4 2 5 8 11 8 K O typ 13 4 K O typ 1 7 8 3 5 8 5 5 8 DETAIL D 3 1 4 2 1 4 15 1 4 13 SUCTION LIQUID W 1 1 8 1 7 8 7 8 K O H 22 A CABINET SIZE H W A DETAIL D A 43 5 16 14 3 16 12...

Page 15: ...Mount Kit Blower Motor Transformer Capacitor Circuit Breaker 60A Heating Element Assembly Filter Tracks Blower Wheel Blower Housing Motor Control Board Filter Door Upper Door Assembly Lower Door Assem...

Page 16: ...s for maximum recommended external static pressure Table 4 B64BM Airflow Data With Horizontal Drain Pan DRY COIL ESP 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 18K A CABINET Low 760 722 676 622 561 492 414 330 M...

Page 17: ...tly Blower off after 15 second delay W1 Y AUX HEAT ON 5 KW Stage 1 Heat on instantly Cool blower on after 3 second delay 10 KW Stage 1 Heat on instantly Cool blower on after 3 second delay 15 KW Stage...

Page 18: ...R C E O Y Thermostat Typical Heat Pump with Standard Air Handler Heat Pump NOTE Jumper between W2 E is required when no OD T Stat is used W1 Y G R C Air Handler W1 Y G R C R C Y W2 O W2 NOTE See step...

Page 19: ...19 LED 1 BLWDTC BLWDTC_R HEAT COOL EAC L 1 L 2 P2 R C G W Y 3A Fuse HEATER P1 Figure 14 Single Stage Control Board...

Page 20: ...G RELAY RELAY Y L2 L1 EAC COOL HEAT W G R C R C L2 L1 7 6 5 4 3 2 1 1 COM 2 CAP 3 CAP 4 HI 5 MED 6 LOW 240 24 V 208 COM TRANSFORMER R C LOCATION OF T CONNECTOR MOTOR 3 SPEED 4 PIN PLUG 18 BLOWER LIMIT...

Page 21: ...21...

Page 22: ...22...

Page 23: ...23...

Page 24: ...t according to strict safety guidelines and instructing the customer on how to operate and maintain the equipment for the life of the product Safety should always be the deciding factor when installin...

Reviews: