background image

6-051344 X2 

5

212iLM Keypad Installation & Programming

Wiring the Bell Output to a Speaker:

The 212iLM keypad has a built in bell button, which triggers a relay output when pressed. This relay is normally open and 
the contact closes when triggered. You can use this relay output to trigger devices that require a momentary closure, such 
as a doorbell. The relay output provides a dry contact, but you can run up to 30 volts AC/DC through it for devices that 
require power to operate. The diagram below shows these connections.

Summary of Contents for Door-Gard 212iLM

Page 1: ...ounting Dimly Lit Areas Description The Door Gard Series 212iLM keypad combines elegant looks with a mullion mount design in a rugged vandal resistant case which you can use for almost any application...

Page 2: ...ill the hole for the wires This may vary depending on the number of conductors required Refer to mounting height below Step 2 Wire the keypad using the diagrams in the following sections Step 3 Mount...

Page 3: ...e connection on your maglock to the negative on the power supply Basic Access Control Using an Electric Door Strike 1 Connect the red V and black V wires to your power supply 2 Connect the blue wire r...

Page 4: ...X input The normally open REX input triggers the main relay for the amount of time you programmed for the master code If the master code is set to toggle the REX only triggers the relay for 5 seconds...

Page 5: ...utput when pressed This relay is normally open and the contact closes when triggered You can use this relay output to trigger devices that require a momentary closure such as a doorbell The relay outp...

Page 6: ...location new code new code Command 30 Set Clear Keypad Options options below defaults in bold 30 option set clear Option Clear Set 0 Audio Keypress Feedback 0 Disabled 1 Enabled 1 Visual Keypress Fee...

Page 7: ...Mode Adding User Codes The following example shows how to program user 2 with a code of 1749 and user 3 with 9328 The master code is 4875 1 Enter Program Mode 99 4875 2 Program User 2 2 1749 code 3 Pr...

Page 8: ...master code The code you are entering is likely not the master code Perform the program mode loopback in the following section to enter program mode and reprogram the master code No LED s are lit on...

Page 9: ...he following loopback connection to enter program mode Power down the unit short the wires in the configuration illustrated then power the unit back up The yellow LED should be flashing Now change you...

Page 10: ...any There are no obligations or liabilities on the part of Nortek Security Control LLC for consequential damages arising out of or in connection with use or performance of this product or other indir...

Page 11: ...6 051344 X2 11 212iLM Keypad Installation Programming PAGE LEFT BLANK INTENTIONALLY...

Page 12: ...12 6 051344 X2 212iLM Keypad Installation Programming 212ilM Mounting Template Copyright 2015 Nortek Security Control LLC...

Reviews: