background image

Special Function

Operation with Smart Phone, Tablet, etc.

This equipment can be controlled with smart phone, tablet, or similar device. The 

GHYLFHPXVWXVHVWDQGDUG$QGURLGRUL26RSHUDWLQJV\VWHP$PD[LPXPRIFRQ

-

trol devices can be used. 

1. 

,QVWDOO*/LIHRQ\RXUGHYLFH8VHRQHRIWKHIROORZLQJPHWKRGV

*RWRWKH$SS6WRUHIRUL26RSHUDWLQJV\VWHPRUWKH*RRJOH3OD\$SSRQ
$QGURLGGHYLFHVDQGVHDUFKIRU*/LIH$IWHUVXFFHVVIXOO\LQVWDOOLQJWKHDSS

icon will appear similar to the one shown below.
The examples shown in this manual are from the iPhone 6. Your display 

PD\ORRNVOLJKWO\GLIIHUHQW$OVRGLVSOD\ZLOOORRNGLIIHUHQWLIWKHDSSKDVEHHQ
XSJUDGHGVLQFHWKHUHOHDVHRIWKLVPDQXDO,IWKHUHLVDGLIIHUHQFHIROORZWKH
LQVWUXFWLRQVWKDWFRPHZLWKWKHVRIWZDUHDSSRYHUWKRVHOLVWHGLQWKLVPDQXDO

Examples are also shown with Celsius temperatures; however the app can 
convert to Fahrenheit.

3DJH

Summary of Contents for GHH092.6KSK4DH

Page 1: ...12 3 5 KSK4DH GHH18 5 2 KSK4DH Please read this owner s manual carefully before operation and retain for future reference 6SHFL FDWLRQV LOOXVWUDWLRQV VXEMHFW WR FKDQJH ZLWKRXW QRWLFH RU LQFXUULQJ REOLJDWLRQV If you have lost the owner s manual please visit www NortekHVAC com for electronic version NORTEK GLOBAL HVAC LLC ...

Page 2: ...Air conditioner and remote should both be in standby status I WKH UHPRWH VLJQDO LVQ W UHFHLYHG E WKH DLU FRQGLWLRQHU SHUIRUP FDOLEUDWLRQ VWHSV DJDLQ 7KH UHPRWH RQO QHHGV WR FDOLEUDWHG RQFH GXULQJ VHWXS With the air conditioner in standby status and the remote within 6 feet 2m press and hold button for 3 seconds The remote controller and air conditioner calibrate automatically The air conditioner w...

Page 3: ...ration with Smart Phone Tablet etc 19 PHUJHQF 2SHUDWLRQ 27 OHDQLQJ 0DLQWHQDQFH 27 Troubleshooting 7URXEOHVKRRWLQJ 30 Installation Installation Clearances 33 Tools for Installation 34 Installation Location Selection 34 Electrical Requirements 35 Indoor Unit Installation 36 9DFXXP 3XPSLQJ 41 Leak Detection 41 Testing and Operation After Installation Checklist 42 Test Operation 42 Connections RQQHFWL...

Page 4: ...HG E D TXDOL HG SURIHVVLRQDO DLOXUH WR FRPSO FRXOG UHVXOW LQ GDPDJH WR WKH HTXLSPHQW RU FDXVH D UH DLOXUH WR FRPSO ZLOO UHVXOW LQ VHYHUH SHUVRQDO LQMXU SURSHUW GDPDJH DQG RU GHDWK DLOXUH WR FRPSO PD UHVXOW LQ VHYHUH SHUVRQDO LQMXU SURSHUW GDPDJH DQG RU GHDWK DLOXUH WR FRPSO PD UHVXOW LQ SHUVRQDO LQMXU DQG RU SURSHUW GDPDJH Indicates important but not hazard related information XVHG WR LQGLFDWH ULV...

Page 5: ...WLRQHU Otherwise it may cause electric shock I WKH VXSSO FRUG LV GDPDJHG LW PXVW EH UHSODFHG E TXDOL HG SHUVRQV Do not wash the air conditioner with water to avoid electric shock Do not spray water on indoor unit It may cause electric shock or malfunction IWHU UHPRYLQJ WKH OWHU GR QRW WRXFK QV WR DYRLG LQMXU R QRW GU OWHU RYHU RSHQ ÀDPH RU ZLWK KDLU GU HU WR DYRLG ZDUSLQJ UH KD DUG 0DLQWHQDQFH PXV...

Page 6: ...QWDFW WKH GHDOHU RU TXDOL HG SURIHVVLRQDOV IRU service 3RZHU FRUG LV RYHUKHDWLQJ RU GDPDJHG 7KHUH V DEQRUPDO VRXQG GXULQJ RSHUDWLRQ Circuit breaker trips off frequently LU FRQGLWLRQHU JLYHV RII EXUQLQJ VPHOO QGRRU XQLW LV OHDNLQJ If the air conditioner malfunctions it may cause electric VKRFN RU UH KHQ WXUQLQJ RQ RU WXUQLQJ RII WKH XQLW E HPHUJHQF operation switch please press this switch with an ...

Page 7: ...cuit break with suitable capacity please note the capacity table Air switch should include PDJQHW EXFNOH DQG KHDWLQJ EXFNOH IXQFWLRQ WR SURWHFW from circuit short and overload LU RQGLWLRQHU VKRXOG EH SURSHUO JURXQGHG QFRUUHFW JURXQGLQJ PD FDXVH HOHFWULF VKRFN Use only an approved power cord Make sure the power supply matches the requirement listed on nameplate Unstable power supply or incorrect ZL...

Page 8: ...ass I electric appliance It must EH SURSHUO JURXQGHG E D SURIHVVLRQDO RWKHUZLVH LW may cause electric shock 7KH HOORZ JUHHQ ZLUH LQ DLU FRQGLWLRQHU PXVW EH XVHG IRU JURXQGLQJ RQO 7KH JURXQGLQJ UHVLVWDQFH VKRXOG FRPSO ZLWK QDWLRQDO HOHFWULF VDIHW UHJXODWLRQV 7KH DSSOLDQFH PXVW EH SRVLWLRQHG VR WKDW WKH SOXJ LV accessible All wires of indoor unit and outdoor unit should be connected by a professiona...

Page 9: ...e installed close to the wall Installation instructions and use of this product are provided by manufacturer 51 1 KDQJHV RU PRGL FDWLRQV WR WKLV XQLW QRW H SUHVVO DSSURYHG E WKH PDQXIDFWXUHU FRXOG GDPDJH WKH equipment and void the warranty This device complies with Part 15 of the FCC Rules Op HUDWLRQ LV VXEMHFW WR WKH IROORZLQJ FRQGLWLRQV 1 this device may not cause harmful interference and 2 this...

Page 10: ...dio com munications RZHYHU WKHUH LV QR JXDUDQWHH WKDW LQWHUIHUHQFH ZLOO QRW occur in a particular installation If this equipment does cause harmful interference to radio or television recep WLRQ ZKLFK FDQ EH GHWHUPLQHG E WXUQLQJ WKH HTXLSPHQW RII DQG RQ WKH XVHU LV HQFRXUDJHG WR WU WR FRUUHFW WKH LQWHUIHUHQFH E RQH RU PRUH RI WKH IROORZLQJ PHDVXUHV 5HRULHQW RU UHORFDWH WKH UHFHLYLQJ DQWHQQD Increa...

Page 11: ...DUHLO QH GRLW SDV SURGXLUH GH EURXLOODJH HW O XWLOLVDWHXU GH O DSSDUHLO GRLW DFFHSWHU WRXW EURXLOODJH UDGLRpOHFWULTXH VXEL PrPH VL OH EURXLOODJH HVW VXVFHS tible d en compromettre le fonctionnement This equipment complies with FCC s and IC s RF radiation exposure limits set forth for an uncontrolled environment The antenna s used for this transmitter must be installed and operated to provide a sep...

Page 12: ... 20 cm de distance des utilisateurs et ne doivent pas être placées près d autres antennes ou émetteurs ou fonctionner avec ceux ci Les installateurs doivent s assurer qu une dis tance de 20 cm sépare l appareil à l exception du com biné des utilisateurs Working Temperature Range NOTICE 7KH RSHUDWLQJ WHPSHUDWXUH UDQJH RXWGRRU WHPSHUDWXUH IRU FRROLQJ RQO XQLW LV 18 C 0 4 F 54 C 129 F for heat pump u...

Page 13: ...Controller Display Air Inlet Temperature Display Air outlet Power Power Cord Parts Indoor Unit NOTICE Illustrations provided apply to different models and are for reference only Actual HTXLSPHQW PD ORRN VOLJKWO GLIIHUHQW Filter 3DJH ...

Page 14: ...4 3 2 17 16 15 14 13 12 11 Remote Control Buttons Display Screen Icons Auto Mode Cool Mode Dry Mode Fan Mode Heat Mode Turbo Fan Speed X FAN Function Set Temp Outdoor Ambient Temp Set Fan Speed Indoor Ambient Temp 6HQG 6LJQDO I Feel Function Set Temperature Sleep Mode Child Lock 8S RZQ 6ZLQJ 5HSODFLQJ LU Operation Mode Temp Display Type Battery Power Set Time Auto Quiet Mode Quiet Mode Humidity Fu...

Page 15: ...LU conditioner operation indicator RQ LQGRRU XQLW ZLOO GLVSOD JUHHQ LQGLFDWRU color may be different on different models and indoor unit will emit a sound 2 XWWRQ 3UHVV RU EXWWRQ RQFH WR LQFUHDVH RU GHFUHDVH WKH WHPSHUDWXUH ROG LQJ RU EXWWRQ PRUH WKDQ VHFRQGV ZLOO FKDQJH WKH VHW WHPSHUDWXUH PRUH TXLFNO 2Q UHOHDVLQJ WKH EXWWRQ DIWHU GHVLUHG VHW WHPSHUDWXUH LV UHDFKHG WKH WHPSHUDWXUH LQGLFDWRU RQ WK...

Page 16: ...J PRGH SUHVV WKLV EXWWRQ WR WXUQ RQ WKH HIW 5LJKW 6LQJ IXQF tion The icon will display on remote Under OFF status press the and button simultaneously to switch between VLPSOH VZLQJ DQG HG PRGH XULQJ WKH VZLWFKLQJ SURFHVV WKH icon will ÀDVK WZLFH 8QGHU HG DQJOH PRGH SUHVV WKLV EXWWRQ WR VZLWFK EHWZHHQ WKH VHWWLQJV LQ WKH sequence shown below No display stops at current position 8 Mode Button Press ...

Page 17: ...om temperature and automatically select a suitable run QLQJ PHWKRG WR PDNH WKH DPELHQW WHPSHUDWXUH FRPIRUWDEOH 9 Button 8QGHU VLPSOH VZLQJ PRGH SUHVV WKLV EXWWRQ WR HQJDJH 8S RZQ 6ZLQJ IXQFWLRQ The icon will display on the remote Under OFF status press and buttons simultaneously to switch between VLPSOH VZLQJ PRGH DQG HG ORXYHU PRGH XULQJ WKH VZLWFKLQJ SURFHVV WKH LFRQ ZLOO ÀDVK WZLFH 8QGHU HG VZL...

Page 18: ...WWRQ ZKHQ UHDFKLQJ WKH FRU UHFW WLPH 3UHVV 2 EXWWRQ WR FRQ UP WKH WLPH 7KH LFRQ ZLOO VWRS EOLQNLQJ Note Clock time defaults to 24 hour mode I QR EXWWRQ LV SUHVVHG IRU VHFRQGV UHPRWH FRQWUROOHU ZLOO TXLW VHWWLQJ VWDWXV 2SHUDWLRQ IRU 7 0 5 21 7 0 5 2 LV WKH VDPH 12 Button Press this button to activate the health function The icon will display Press this EXWWRQ DJDLQ WR DFWLYDWH DQG KHDOWK DQG DLU LQ...

Page 19: ...cator displays current temperature and automatically returns to display set WHPSHUDWXUH DIWHU WKUHH WR YH VHFRQGV 14 X Fan Button 3UHVVLQJ WKLV EXWWRQ LQ 22 RU 5 PRGHV WKH icon is displayed and the LQGRRU IDQ ZLOO FRQWLQXH WR RSHUDWH IRU PLQXWHV EORZLQJ HYHQ LI WKH XVHU VHOHFWV to turn the unit off The continued air movement helps to dry out the indoor coil DYRLGLQJ WKH JURZWK RI PROG 7KH DQ IXQFW...

Page 20: ...VHWWLQJ GDWD KDV EHHQ entered Once successfully entered the timer and temperature display will return to normal 5 7R FKHFN WKH VOHHS FXUYH VHWWLQJ XQGHU 6OHHS HQWHU WKH VOHHS VHWWLQJ PRGH DV GHVFULEHG DERYH EXW GR QRW FKDQJH WKH WHPSHUDWXUH VHWWLQJ 3UHVV WKH 7HPS EXWWRQ HDFK WLPH WR FRQ UP WKH VHWWLQJ DQG UHYLHZ WKH QH W VHWWLQJ NOTE If no button is pressed for 10 seconds the remote will exit the ...

Page 21: ...DXWR DQG FDQ W EH FKDQJHG 8QGHU HQHUJ VDYLQJ IXQFWLRQ VHW WHPSHUDWXUH FDQ W EH DGMXVWHG 6OHHS IXQFWLRQ DQG HQHUJ VDYLQJ IXQFWLRQ FDQ W RSHUDWH DW WKH VDPH WLPH I HQHUJ VDYLQJ IXQFWLRQ KDV EHHQ VHW XQGHU FRROLQJ PRGH SUHVVLQJ VOHHS EXWWRQ ZLOO FDQFHO HQHUJ VDYLQJ IXQFWLRQ I VOHHS IXQFWLRQ KDV EHHQ VHW XQGHU FRROLQJ PRGH VWDUWLQJ HQHUJ VDYLQJ IXQFWLRQ ZLOO FDQFHO VOHHS IXQFWLRQ 8 C 46 F Heating Func...

Page 22: ...HPRWH VLJQDO I WKLV LV WKH FDVH PRYH WKH UHPRWH FORVHU WR WKH DLU FRQGL tioner KHQ UHSODFLQJ EDWWHULHV XVH WKH VDPH W SH RI QHZ EDWWHULHV KHQ RX GRQ W XVH UHPRWH FRQWUROOHU IRU D ORQJ WLPH SOHDVH WDNH RXW WKH batteries If the display on remote controller is fuzzy or there s no display please replace batteries Notice Batteries Remove Battery box cover Battery level Operation Guide 1 IWHU WXUQLQJ RQ...

Page 23: ... WKH RRJOH 3OD SS RQ QGURLG GHYLFHV DQG VHDUFK IRU LIH IWHU VXFFHVVIXOO LQVWDOOLQJ WKH DSS icon will appear similar to the one shown below The examples shown in this manual are from the iPhone 6 Your display PD ORRN VOLJKWO GLIIHUHQW OVR GLVSOD ZLOO ORRN GLIIHUHQW LI WKH DSS KDV EHHQ XSJUDGHG VLQFH WKH UHOHDVH RI WKLV PDQXDO I WKHUH LV D GLIIHUHQFH IROORZ WKH LQVWUXFWLRQV WKDW FRPH ZLWK WKH VRIWZD...

Page 24: ...on the AC WiFi 1 Turn the AC on Make sure the remote controller matches the air conditioner 2 Press and hold the WiFi button on the remote controller for at least 3 sec onds If WiFi icon is shown the WiFi function is turned on 3 R WR WKH L L VHWWLQJ RI RXU SKRQH DQG VHDUFK IRU WKH ZLUHOHVV QHWZRUN IRU example G A0B40030 Connect the network 4 Input the default password 12345678 to connect the netwo...

Page 25: ... WR 1HWZRUN 6HWWLQJ WR PRGLI QHWZRUN QDPH H J P KRPH DQG password refer to the attachment safe mode and password instruction 7 IWHU PRGLI LQJ QDPH DQG SDVVZRUG FOLFN WR H LW OLFN 2 LQ WKH SURPSW ER OLFN 2 DJDLQ WR QLVK WKH PRGL FDWLRQ 7KH VFUHHQ UHWXUQ WR WKH DLU conditioner screen and the AC list will be blank 8 LW WKH DSSOLFDWLRQ DQG HQWHU RXU GHYLFH V L L 6HWWLQJ 7KHQ RX ZLOO VHH WKH QHWZRUN RX...

Page 26: ...e completed within 2 minutes I VKRUW GLVWDQFH FRQWURO IDLOV SOHDVH FKHFN WKH IROORZLQJ LWHPV 7URXEOHVKRRWLQJ RPPRQ 1HWZRUN 6HWWLQJ DLOXUH Make sure power is turned on to air conditioner Make sure air conditioner WiFi function is turned on 0DNH VXUH RXU SKRQH V L L VHOHFWV WKH FRUUHVSRQGLQJ DLU FRQGLWLRQLQJ XQLW 5HVHW WKH DLU FRQGLWLRQHU ZLWK WKH UHPRWH FRQWUROOHU DQG JR EDFN WR VWHS R WR L L VHWWL...

Page 27: ...RU HDW 5HIHU WR WKH 0RGH VHWWLQJ LQ WKH UHPRWH FRQWURO VHFWLRQ IRU more information 2 7HPSHUDWXUH 6HOHFW WKH LQGRRU WHPSHUDWXUH VHWWLQJ 3 DQ 6HWV WKH IDQ VSHHG I WKH XQLW LV RSHUDWLQJ LQ TXLHW IDQ VSHHG LQ KHDWLQJ RU FRROLQJ PRGH DGMXVWLQJ WKH IDQ VSHHG KHUH ZLOO FDQFHO WKH TXLHW IDQ VSHHG VHWWLQJ 5HIHU WR DQ RSHUDWLRQ LQ WKH UHPRWH FRQWURO VHFWLRQ 3DJH ...

Page 28: ...s added to the air conditioner E heater is not available for this model 3 6ZLQJ 6HWV WKH RVFLOODWLRQ DQJOH RI WKH ORXYHUV IRU 8S RZQ RU HIW 5LJKW 6ZLQJ 6OLGH WKH EORFNV DOO WKH ZD DSDUW IRU IXOO RVFLOODWLRQ 6OLGH WKHP WRJHWKHU WR GHFUHDVH WKH DLU ÀRZ DQJOH KHQ VHWWLQJ HIW 5LJKW 6ZLQJ WKH 5HJLRQDO 6ZLQJ VHWWLQJV ZLOO EH PDLQWDLQHG KHQ VHWWLQJ 8S RZQ 6ZLQJ WKH 5HJLRQDO 6ZLQJ VHWWLQJV ZLOO EH ORVW 6H...

Page 29: ... LFRQ WR PDWFK actual installation location 4 3 0RYH WKH SHUVRQ LFRQ WR UHÀHFW UHODWLYH ORFDWLRQ RI SHRSOH WR WKH DLU FRQGL WLRQHU WR DGMXVW DLU ÀRZ FRYHUDJH DUHD I WKH 8S RZQ 6ZLQJ VHWWLQJ LV UHVHW WKH 5HJLRQDO 6ZLQJ VHWWLQJ ZLOO EH WXUQHG RII 8S RZQ 6ZLQJ DQG 5HJLRQDO 6ZLQJ FDQ RQO EH VHOHFWHG XQGHU FRROLQJ RU KHDWLQJ PRGHV 7KH HIW 5LJKW 6ZLQJ VHWWLQJV ZLOO DXWRPDWLFDOO EH VHW EDVHG RQ WKH LQSXW...

Page 30: ...d level selec tions vary by model and size 4 5 3RZHU VDYLQJ GMXVWV WKH DLU FRQGLWLRQHU IUHTXHQF IDQ VSHHG DQG WHPSHUD WXUH VHWWLQJ DXWRPDWLFDOO WR XVH WKH OHDVW DPRXQW RI HQHUJ EDVHG RQ DFWXDO indoor and outdoor temperature Operation with Smart Phone Tablet etc 3DJH ...

Page 31: ...n it will operate under auto mode Panel Display panel Auxiliary button 8VH LQVXODWHG REMHFW to press the auxiliary button Clean surface of indoor unit with soft dry cloth NOTICE R QRW UHPRYH WKH SDQHO ZKHQ FOHDQLQJ Cleaning Maintenance WARNING WARNING 7XUQ RII DLU FRQGLWLRQHU DQG GLVFRQQHFW WKH SRZHU EHIRUH FOHDQLQJ WR avoid electric shock Do not wash air conditioner with water to avoid electric s...

Page 32: ... LQMXU DQG GDP DJH WR WKH XQLW 1HYHU GU OWHU RYHU RSHQ ÀDPH RU ZLWK KDLU GU HU WR DYRLG ZDUSLQJ RU UH 1 Open Panel Pull out the panel and raise it up as shown below 2 Remove Filter 5HPRYH WKH OWHU DV shown below 3 Clean Filter 8VH GXVW FDWFKHU WR FOHDQ WKH OWHU I WKH OWHU LV YHU GLUW XVH ZDWHU Note water can not be warmer than HW OWHU VLW LQ FRRO dry place until dry 4 Reinstall Filter QVWDOO WKH O...

Page 33: ...WR PDNH VXUH OWHU LV FOHDQ 4 KHFN LI GUDLQDJH SLSH LV GDPDJHG Notice Preseason Checklist 1 Disconnect power supply 2 OHDQ OWHU DQG LQGRRU XQLW SDQHO Notice Post Season Checklist Disposal and Recycling 1 0DQ SDFNLQJ PDWHULDOV DUH UHF FODEOH 3OHDVH GLVSRVH RU UHF FOH UH sponsibly 2 Contact local dealer or service center for the proper disposal method 3DJH ...

Page 34: ...RWH FRQWUROOHU SRLQWLQJ DW WKH UHFHLYLQJ ZLQGRZ 6HOHFW SURSHU DQJOH DQG SRLQW the remote controller at the UHFHLYLQJ ZLQGRZ RQ LQGRRU unit Is sensitivity of remote con troller low fuzzy display or no GLVSOD Check the batteries Replace them if needed 1R GLVSOD ZKHQ RSHUDWLQJ UHPRWH FRQWUROOHU Check whether remote controller appears to be dam DJHG I HV UHSODFH LW OXRUHVFHQW ODPS LQ URRP Move the rem...

Page 35: ...erature can t be adjusted V XQLW RSHUDWLQJ XQGHU DXWR PRGH 7HPSHUDWXUH FDQ W EH DGMXVW ed under auto mode Switch the operation mode if you QHHG WR DGMXVW WHPSHUDWXUH Does the desired temperature exceeds the set temperature UDQJH 6HW WHPSHUDWXUH UDQJH 16 30 C 61 86 F Poor cooling heat ing performance V WKH VXSSO YROWDJH WRR ORZ If temporary occurrence ZDLW XQWLO YROWDJH UHWXUQV WR normal RQWDFW D T...

Page 36: ...s DWHU ÀRZLQJ QRLVH DV DLU FRQGLWLRQHU MXVW EHHQ WXUQHG RQ RU WXUQHG RII The noise is the sound of the unit which is normal Cracking noise DV DLU FRQGLWLRQHU MXVW EHHQ WXUQHG RQ RU WXUQHG RII This is the sound of friction FDXVHG E H SDQVLRQ DQG RU contraction of panel or other SDUWV GXH WR WKH FKDQJH RI temperature Error Code Troubleshooting C5 3OHDVH FRQWDFW TXDOL HG SURIHVVLRQDO IRU VHUYLFH E5 W...

Page 37: ...llation Clearances LPHQVLRQ EHORZ VKRZ PLQLPXP FOHDUDQFHV IURP REVWDFOHV ZDOOV FHLOLQJ ÀRRU etc allowed around indoor unit Bottom 250cm 8 ft Top 15cm 6 in Side 15cm 6 in Front 300cm 10 ft Side 15cm 6 in 3DJH ...

Page 38: ...r other fumes in the air 5 3ODFHV ZLWK KLJK VXOIXU JDV FRQFHQWUDWLRQ LQ WKH DLU 6 Other places with special circumstances 7 Do not use the unit in a laundry Indoor Unit 1 There should be no obstruction near air inlet and air outlet 2 Select a location where the condensation water can be drained easily and won t drip on people animals other s property etc 3 Select a location which is convenient to ...

Page 39: ...XVW EH UHSODFHG E TXDOL HG SHUVRQQHO 8 7KH UHIULJHUDQW SLSLQJ ZLOO EH KRW H VXUH WR NHHS DOO FDEOHV DZD IURP FRSSHU WXELQJ 9 7KH DSSOLDQFH VKDOO EH LQVWDOOHG LQ DFFRUGDQFH ZLWK QDWLRQDO ZLULQJ UHJXODWLRQV Grounding Requirement 1 7KH DLU FRQGLWLRQHU LV D ODVV HOHFWULF DSSOLDQFH W PXVW EH SURSHUO JURXQG HG ZLWK VSHFLDOL HG JURXQGLQJ GHYLFH E D SURIHVVLRQDO RU LW PD FDXVH HOHF tric shock 2 7KH HOORZ ...

Page 40: ...QWLQJ IUDPH RQ WKH ZDOO PDNH VXUH LW LV OHYHO 0DUN WKH screw locations on the wall 2 Drill holes in the wall for screws Insert plastic expansion or anchor in the hole 3 WWDFK WKH ZDOO PRXQWLQJ IUDPH RQ WKH ZDOO ZLWK WDSSLQJ VFUHZV 67 7 DQG WKHQ FKHFN LI WKH IUDPH LV UPO LQVWDOOHG Step three open piping hole 1 6HOHFW WKH ORFDWLRQ IRU WKH RXWOHW SLSH DQG PDNH DQ RSHQLQJ LQ WKH ZDOO 7KH SRVLWLRQ RI S...

Page 41: ...oner 2 After selection position of outlet SLSH OHIW RU ULJKW FXW RII WKH FRUUH VSRQGLQJ KROH RQ ERWWRP RI FDVH 6WHS YH FRQQHFW SLSH WR RXWGRRU unit 1 OLJQ WKH SLSH MRLQW DW WKH FRUUHVSRQGLQJ valve 2 7LJKWHQ WKH XQLRQ QXW E KDQG 3 GMXVW WKH WRUTXH IRUFH E UHIHUULQJ WR WKH IROORZLQJ VKHHW 3ODFH WKH RSHQ HQG ZUHQFK RQ WKH SLSH MRLQW DQG SODFH WKH WRUTXH ZUHQFK RQ WKH XQLRQ QXW 7LJKWHQ WKH XQLRQ nut w...

Page 42: ... connect wire of in door unit 1 Open the panel remove the screw on WKH ZLULQJ FRYHU DQG WKHQ WDNH GRZQ the cover GG LQVXODWLQJ SLSH LQ WKH indoor drain hose in order to prevent condensation The plastic expansion anchors are not provided Note Open end Wrench Union Nut Pipe Torque Wrench Indoor Pipe Step six install drain hose 1 Connect the drain hose to the outlet pipe of indoor unit 2 6HFXUH WKH M...

Page 43: ...QJ the electrical box cover Cable cross Hole Power Connection Cord 4 5HSODFH ZLULQJ FRYHU DQG WLJKWHQ WKH VFUHZ 5 Close the panel Note All wires of indoor unit and outdoor unit should be connected by a professional 2QO VLQJOH XQEURNHQ HOHFWULFDO ZLUHV VKRXOG EH XVHG 6SOLFHG ZLUHV DUH QRW DO lowed RU DLU FRQGLWLRQHU PRGHOV ZLWK HOHFWULFDO SOXJ WKH RXWOHW PXVW EH UHDFKDEOH DIWHU QLVKLQJ LQVWDOODWLRQ...

Page 44: ...rol wire FDQ W EH FURVVHG RU ZLQGLQJ The drain hose should be bound at the bottom Note HHS EHQGV LQ GUDLQ OLQH WR D PLQLPXP QXPEHU DQG GHJUHH WR SUHYHQW EORFNDJH Note 2 5HVHUYH D FHUWDLQ OHQJWK RI GUDLQ hose and power cord for installation ZKHQ ELQGLQJ WKHP KHQ ELQGLQJ WR D FHUWDLQ GHJUHH VHSDUDWH WKH indoor power and then separate the drain hose 3 Bind them evenly 4 7KH OLTXLG SLSH DQG JDV SLSH V...

Page 45: ...e RI PDQLIROG JDXJH UHPDLQV DW Leak Detection 1 LWK OHDNDJH GHWHFWRU KHFN LI WKHUH LV OHDNDJH ZLWK OHDNDJH GHWHFWRU 2 With soapy water I OHDNDJH GHWHFWRU LV QRW DYDLODEOH SOHDVH XVH VRDS ZDWHU IRU OHDNDJH GHWHF tion Apply soapy water at the suspected leak location and keep it there for more than 3min If you see air bubbles there is a leak Liquid Valve Gas Valve 5HIULJHUDQW KDUJLQJ 9HQW 5HIULJHUDQW...

Page 46: ...ord match the speci FDWLRQ W PD FDXVH PDOIXQFWLRQ RU GDPDJH Is there any obstruction in the air inlet DQG RXWOHW W PD FDXVH LQVXI FLHQW FRROLQJ KHDW LQJ FDSDFLW Is the dust and debris from installation UHPRYHG W PD FDXVH PDOIXQFWLRQ RU GDPDJH UH WKH JDV YDOYH DQG OLTXLG YDOYH RI FRQQHFWLRQ SLSH RSHQ FRPSOHWHO W PD FDXVH LQVXI FLHQW FRROLQJ KHDW LQJ FDSDFLW V WKH LQOHW DQG RXWOHW RI SLSLQJ KROH FRY...

Page 47: ...W DPRXQW DGGLWLRQDO OHQJWK RI OLTXLG SLSH î DGGLWLRQDO UHIULJHUDQW FKDUJLQJ DPRXQW SHU IRRW DVLQJ RQ WKH OHQJWK RI VWDQGDUG SLSH DGG UHIULJHUDQW DFFRUGLQJ WR WKH UH TXLUHPHQW DV VKRZQ LQ WKH WDEOH 7KH DGGLWLRQDO UHIULJHUDQW FKDUJLQJ DPRXQW SHU IRRW LV GLIIHUHQW DFFRUGLQJ WR WKH GLDPHWHU RI OLTXLG SLSH 6HH WKH IROORZLQJ table RROLQJ Capacity 0D OHQJWK of connec tion pipe 0D KHLJKW difference WX K 1...

Page 48: ...LRQDO UHIULJHUDQW FKDUJLQJ DPRXQW IRU 5 Diameter of connection pipe mm in 2XWGRRU XQLW WKURWWOH J P R IW Liquid Pipe Gas Pipe RROLQJ 2QO RROLQJ HDWLQJ Ø 9 52 or 12 RU Ø 6 or 9 52 RU Ø 16 or 19 RU Ø 19 or 22 2 RU Ø 25 4 or 31 8 RU 3DJH ...

Page 49: ...WDEOH LQVXODWLQJ SLSH D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe Note LV GLIIHUHQW DFFRUGLQJ WR WKH GLDP eter please refer to the table below Outer diameter mm in A mm in Max Min a a a 2 4 3 32 F Inspection KHFN WKH TXDOLW RI H SDQGLQJ SRUW If there is any blemish expand the SRUW DJDLQ DFFRUGLQJ WR WKH VWHSV above P...

Page 50: ...3DJH ...

Page 51: ...3DJH ...

Page 52: ...66129923003 6SHFL FDWLRQV LOOXVWUDWLRQV VXEMHFW WR FKDQJH ZLWKRXW QRWLFH RU LQFXUULQJ REOLJDWLRQV 2 DOORQ 02 1RUWHN OREDO 9 OO 5LJKWV 5HVHUYHG 3DJH ...

Reviews: