IMPORTANT:
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
1. INTRODUCTION
Please read these instructions completely and carefully
before installing and operating the furnace.
MODELS O4HD-091A-12-FB, O4HD-091A-14-FA-
DV, AND O4HD-091A-V-FA
Models O4HD-091A-12-FB, O4HD-091A-14-FA-DV and
O4HD-091A-V-FA are oil fired forced air up-flow furnaces
with an output capacity range of 59,000 BTU/Hr. to
86,000 BTU/Hr.
DO NOT USE GASOLINE, CRANK CASE OIL, OR
ANY OIL CONTAINING GASOLINE.
All models are CSA listed, (NRTL/C) for use with No. 1
(Stove) and No. 2 (Furnace) Oil. Please refer to the
tables in Appendix A for performance and dimensional
data.
In Canada, the installation of the furnace and related
equipment shall be installed in accordance with the
regulations of CAN/CSA - B139,
Installation Code for Oil-
Burning Equipment
, as well as in accordance with local
codes.
In the United States of America, the installation of the
furnace and related equipment shall be installed in
accordance with the regulations of NFPA No. 31,
Standard for the Installation of Oil-Burning Equipment
, as
well as in accordance with local codes.
Regulations prescribed in the National Codes and Local
regulations take precedence over the general
instructions provided on this installation manual. When in
doubt, please consult your local authorities.
All models are shipped assembled and pre-wired. The
furnace should be carefully inspected for damage when
being unpacked.
2. HEAT LOSS
The maximum hourly heat loss for each heated space
shall be calculated in accordance with the procedures
described in the manuals of the Heating, Refrigeration
and Air Conditioning Institute of Canada (HRAI), or by
other means prescribed, or approved by the local
authority having jurisdiction.
In the United States, Manual J. titled, "Load Calculation"
published by the Air Conditioning Contractors of
America, describes a suitable procedure for calculating
the maximum hourly heat loss.
3. LOCATION OF UNIT
The furnace should be located such that the flue
connection to the chimney is short, direct and
consists of as few elbows as possible. When
possible, the unit should be centralized with respect
to the supply and return air ductwork. A central
location minimizes the trunk duct sizing. All models
may be installed on combustible floors.
The minimum installation clearances are listed in
Table 1.
Table 1: Clearances – (Inches)
Clearance to Combustibles
O4HD-091A-12-FB, O4HD-
091A-14-FA-DV and O4HD-
091A-V-FA
Location
Up flow
Top 1
Bottom 0
S/A Plenum
1
Rear 1
Sides 1
Front
1**
Flue Pipe
9*
Enclosure Closet
*18 in. in USA
** 24 in. required for service clearance
HEAT EXCHANGER SUPPORT SCREWS
Before final placement of the furnace, the heat
exchanger support screws shown in the picture may
be removed. This may be preferable if the furnace
rear panel will be inaccessible after installation. The
screws must be removed if the heat exchanger must
be removed from the cabinet.
3
Summary of Contents for O4HD-091A-12-FB
Page 34: ...34...