16
Installing ISDN BRI hardware
4
Install the S/T Interface Linecards (SILCs) and/or U Interface
Linecards (UILCs) or Basic Rate Signaling Concentrators (BRSCs).
5
Connect ISDN BRI terminals. This procedure comprises the
following:
•
Connect the system to the Main Distribution Frame (MDF).
•
Cross-connect the MDF.
•
Connect ISDN BRI terminals to the DSL.
•
Initialize the ISDN BRI terminals.
—End—
Procedure 1
Selecting the card slots
Step
Action
To install ISDN BRI cards, perform the following steps:
1
Identify all the slots that can contain the ISDN BRI cards. First
identify the modules with unused network and peripheral card slots
and then remove the covers from the identified modules. To identify
the modules, use the following Print Programs.
•
LD 22 to print the system configuration and identify unused
network card slots to install MISPs
•
LD 20 to list unused IPE card slots to install SILCs, UILCs and
BRSCs
Table 2 "ISDN BRI card location" (page 16)
lists the modules that
can house ISDN BRI cards.
Table 2
ISDN BRI card location
Modules
Supported
Systems
SILCs,
UILCs,
BRSCs
MISPs
NT4N41
Core/Network Module
Large
Systems
—
Network
slots 0-7
NT8D35
Network Module
81C CPPII
—
Network
slots 5-12
NT8D37
IPE Module
All systems
IPE slots
0-15
—
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318
01.02
Standard
Release 5.0
20 June 2007
Copyright © 2003-2007, Nortel Networks
.
Summary of Contents for 1000 Con?guration guide
Page 107: ......