Installation procedures
77
The power source must not feed the power back into the DSL
through the RJ-45 wall outlet, only to the local ISDN BRI terminal.
The power adapter is normally supplied with the terminal.
Figure 28 "Connecting the ISDN BRI terminal to the S/T interface"
(page 78)
illustrates an ISDN BRI terminal connection to an S/T
interface.
Figure 29 "Connecting the ISDN network terminator to the
U interface" (page 79)
illustrates an ISDN BRI terminal connection to
a U interface.
3
Enter the Static TEI at the terminal.
Note: Do not perform this step to assign Dynamic TEIs since
they are automatically assigned.
4
Enter the Service Profile ID number at the terminal.
For detailed information about this procedure, refer to the terminal
user guide.
5
Repeat
step 1
to
step 4
for each ISDN BRI terminal.
—End—
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318
01.02
Standard
Release 5.0
20 June 2007
Copyright © 2003-2007, Nortel Networks
.