Basic Configuration and Setup
Ongoing Configuration
Centillion 1200N ATM Switch User Manual
8-5
NTP 297-8103-903
Ongoing Configuration
Interface, ILMI,
and SVC
Signaling
This section describes how to configure different interface types and PVCs.
Interface Configuration
The
SET INTERFACE
command sets the type of interface, such as Private UNI,
Private NNI, or Public UNI. Each interface complies with ATM Forum
specifications and has its own unique applications. If you want to keep the default
interface configuration, you can skip this section.
1.
Display the current configuration of the interfaces.
DISPLAY interface
Line Interface Physical layer
Forum/ITU Unassigned/Idle Valid
VPI/VCI
00 pri_UNI
<dependent on card type>
ATM Forum Unassigned 6/8
01 pri_UNI
<dependent on card type>
ATM Forum Unassigned 6/8
02 pri_UNI
<dependent on card type>
ATM Forum Unassigned 6/8
03 pri_UNI
<dependent on card type>
ATM Forum Unassigned 6/8
To display only a particular interface, use the following command:
DISPLAY interface [slot number][port number]
The default response should look something like this:
Line:
00
Interface type
pri_UNI
Physical layer:
<dependent on card type>
Forum/ITU:
ATM Forum
Unassigned/Idle:
Unassigned
Valid VPI:
6
Valid VCI:
8
Because the default configuration is already active and in service, you must
remove all connections before changing a port configuration.
2.
Suspend SVC activity for the port that you are modifying.
SET svcline [slot number][port number] [vpi number]
suspend
Example:
SET SVCline 23 0 suspend
3.
Delete the ILMI signaling PVC connection.
DELETE ilmi [slot number][port number] [vpi number]
This command deletes the ILMI PVC connection for the specified port. The
default VPI/VCI of ILMI is 0/16.
Example:
DELETE ILMI 23 0