Chapter 2 Installation Process

320846-A

 

Supplying power to the switch

Supply power after installing the unit in a rack or on a flat surface. 

Note: 

Use of both the rear and front power switches is required for full switch operation.

Connecting the power supply

Connect the power supply using the power cord ordered for this location.

To connect the power supply, follow these steps:

1

Connect the power cord to the power receptacle on the unit’s rear panel.

2

Plug the cord into a properly fused outlet.

3

Set the rear power switch to the “

|

” ON position.

4

Switch the power on by pressing the power button on the front panel. The 
system power LED turns green to indicate that power is being supplied.

For normal use, switch the power on. Always disconnect the power before 
removing the unit from its installed location. Disconnect the power by setting the 
rear panel power switch to OFF.

Setting up terminal access to the switch

The Nortel Secure Network Access Switch 4050 has a console port for system 
diagnostics and configuration. This section explains how to connect a terminal to 
the console port in order to establish a first console connection. 

For instructions on viewing and configuring system settings using either a console 
connection or network connection (via Telnet or SSH), see the 

Nortel Secure 

Network Access Switch 4050 User Guide

(320818-A).

Summary of Contents for 4050

Page 1: ...Part No 320846 A December 2005 4655 Great America Parkway Santa Clara CA 95054 320846 A Nortel Secure Network Access Switch 4050 Installation Guide ...

Page 2: ...ction and disclosure are as set forth in the Commercial Computer Software Restricted Rights clause at FAR 52 227 19 Statement of conditions In the interest of improving internal design operational function and or reliability Nortel Networks reserves the right to make changes to the products described in this document without notice Nortel Networks does not assume any liability that may occur due t...

Page 3: ...idential area is likely to cause harmful interference in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense ICES statement Canada only Canadian Department of Communications Radio Interference Regulations This digital apparatus Nortel Secure Network Access Switch 4050 does not exceed the Class A limits for radio noise emissi...

Page 4: ...only This device has been approved for use in Business applications only per the Class A requirements of the Republic of Korea Ministry of Information and Communications MIC This device may not be sold for use in a non business application Observe the Regulatory Marking label on the bottom surface of the chassis for specific certification information pertaining to this model Each model in the Ethe...

Page 5: ...arez México D F 03900 Tel 52 5 480 2100 Fax 52 5 480 2199 Input Nortel Secure Network Access Switch 4050 100 240 VAC 6 3 A 50 60 Hz Información NOM unicamente para México La información siguiente se proporciona en el dispositivo o en los dispositivos descritos en este documento en cumplimiento con los requisitos de la Norma Oficial Méxicana NOM Exportador Nortel Networks 600 Technology Park Drive ...

Page 6: ...6 320846 A ...

Page 7: ...l 18 Rear panel 21 Chapter 2 Installation Process 25 Safety precautions 25 Ventilation safety 25 Electrical safety 26 Mechanical safety 26 Installing the switch in a rack 27 Installing the switch on a shelf or tabletop 27 Supplying power to the switch 28 Connecting the power supply 28 Setting up terminal access to the switch 28 Terminal requirements 29 Console connector and pin assignments 29 Esta...

Page 8: ...846 A Appendix A Specifications 33 Hardware and power supply specifications 33 Console port setup parameters 35 LAN connection speeds 35 Regulatory specifications 35 Appendix B Safety Message Translations 39 Index 45 ...

Page 9: ...e you begin Ensure that the area where you install the Nortel Secure Network Access Switch 4050 meets the following environmental requirements Ambient temperature between 32 F and 104 F 0 C and 40 C Relative humidity between 5 and 85 non condensing No nearby heat sources such as hot air vents or direct sunlight No nearby sources of severe electromagnetic noise No excessive dust Adequate power sour...

Page 10: ... Enter show ip alerts routes braces Indicate required elements in syntax descriptions where there is more than one option You must choose only one of the options Do not type the braces when entering the command Example If the command syntax is show ip alerts routes you must enter either show ip alerts or show ip routes but not both brackets Indicate optional elements in syntax descriptions Do not ...

Page 11: ...in command syntax descriptions Also indicates new terms and book titles Where a variable is two or more words the words are connected by an underscore Example If the command syntax is show at valid_route valid_route is one variable and you substitute one value for it plain Courier text Indicates command syntax and system output for example prompts and system messages Example Set Trap Monitor Filte...

Page 12: ...ract for your Nortel product from a distributor or authorized reseller contact the technical support staff for that distributor or reseller for assistance If you purchased a Nortel service program use the www nortel com support web page to contact Nortel for assistance ...

Page 13: ...ss Switch 4050 Installation Guide Figures Figure 1 Front panel view with bezel 18 Figure 2 Bezel removal 19 Figure 3 Front panel view without bezel 19 Figure 4 Bezel attachment 20 Figure 5 Rear panel view 21 Figure 6 Setup menu 30 ...

Page 14: ...14 Figures 320846 A ...

Page 15: ...cators 22 Table 5 Ports 3 and 4 LED status indicators 22 Table 6 Console configuration parameters 29 Table 7 Pinouts for DB 9 console connector 29 Table 8 Hardware specifications 33 Table 9 Power supply specifications 34 Table 10 Console port setup parameters 35 Table 11 LAN connection speeds 35 Table 12 Safety specifications 35 Table 13 Emissions specifications 36 Table 14 Certification marks 36 ...

Page 16: ...16 Tables 320846 A ...

Page 17: ...h American power cord To meet North American power specifications Not supplied if an alternate country cord is ordered European power cord To meet European power specifications Not supplied if an alternate country cord is ordered Console cable To connect the Nortel SNAS 4050 to a personal computer or local terminal Bezel adapter kit with 2 brackets and 4 rubber feet To install the Nortel SNAS 4050...

Page 18: ...h 4050 front panel view Table 2 describes front panel features Figure 1 Front panel view with bezel Table 2 Front panel features Indicator or Button Description Amber system status LED On when system needs attention due to power supply fan CPU or device temperature problems Hard disk drive activity LED Blinks during hard disk drive activity Reset button Reboots the switch Power button Turns on swi...

Page 19: ...To remove the bezel follow these steps 1 On the left front of the unit locate and open the bezel release flap Figure 2 2 Grasp the bezel and slide the bezel to the right until disengaged 3 Remove the bezel from the faceplate Figure 2 Bezel removal Figure 3 shows the front panel without the bezel Figure 3 Front panel view without bezel CD Drive Face plate LEDs and buttons USB Connectors ...

Page 20: ...eration To attach the bezel follow these steps 1 Align the bezel on the faceplate slightly to the right of the front panel 2 With the release flap open engage the bezel onto the track and slide it to the left until it locks into place Figure 4 3 Close the release flap Figure 4 Bezel attachment ...

Page 21: ...are on board ports Ports 3 and 4 are NIC Network Interface Controller ports Status LEDs for each port are located above the port Port 1 LED locations are shown in Figure 5 Table 3 Rear panel features Item Purpose Power supply fan Cools the power supply AC power socket Connects to the power source Console port Connects to the terminal or PC terminal emulator LAN ports Connect to the network Power s...

Page 22: ...rt and network device is good When the left LED is flashing the port is sending or receiving network data 1000 Mb s On or flashing On or flashing Port operates at 1000 Mb s Cable connection between the port and network device is good When the LEDs are flashing the port is sending or receiving network data All speeds Off Off One or more above conditions is not met Table 5 Ports 3 and 4 LED status i...

Page 23: ... Guide All speeds Flashing Port is sending or receiving network data Flash frequency varies with the amount of network traffic All speeds Off Off One or more above conditions is not met Table 5 Ports 3 and 4 LED status indicators continued Port speed Left LED Right LED Status ...

Page 24: ...24 Chapter 1 Overview 320846 A ...

Page 25: ...erating ambient temperature of the equipment can be higher than the ambient temperature of the room Take appropriate steps to ensure that the device does not overheat Topic Page Safety precautions 25 Installing the switch in a rack 27 Installing the switch on a shelf or tabletop 27 Supplying power to the switch 28 Setting up terminal access to the switch 28 Troubleshooting installation 31 Caution ...

Page 26: ... of exit from the Nortel Secure Network Access Switch 4050 are carefully positioned Mechanical safety For rack mounted installation ensure that racks are stable and securely installed Danger Use only power cords that have a grounding path Without a proper ground a person who touches the switch is in danger of receiving an electrical shock Lack of a grounding path to the switch may result in excess...

Page 27: ...ront brackets and into the rack frame Continue the installation process by connecting the power supply See Supplying power to the switch on page 28 Installing the switch on a shelf or tabletop Install the Nortel Secure Network Access Switch 4050 on a flat surface using the supplied bezel adapter kit with 4 rubber feet Follow these steps to install the unit on a flat surface 1 Identify a stable she...

Page 28: ...y pressing the power button on the front panel The system power LED turns green to indicate that power is being supplied For normal use switch the power on Always disconnect the power before removing the unit from its installed location Disconnect the power by setting the rear panel power switch to OFF Setting up terminal access to the switch The Nortel Secure Network Access Switch 4050 has a cons...

Page 29: ... Access Switch 4050 Console connector and pin assignments The console port on the unit is a DCE female DB 9 connector Table 7 describes pin signal and I O assignments for this connector Table 6 Console configuration parameters Parameter Value Baud Rate Data Bits Parity Stop Bits Flow control 9600 8 None 1 None Table 7 Pinouts for DB 9 console connector DB 9 Console Port Connector Pin Signal I O De...

Page 30: ...assword prompt enter the administrator password The default administrator password is admin Note To ensure continuing system security change the default password to the password of your choice after you successfully configure the switch After password verification the system displays the Setup menu with the information shown in Figure 6 Figure 6 Setup menu Continue the set up process using instruc...

Page 31: ...cations listed in Appendix A Table 9 on page 34 for information Ensure that the power switch on the rear of the system is turned on Press the front panel power button If the system does not power on correctly after checking these items contact Nortel Technical Support at www nortel com support No display text If the system powers on and there are no boot messages or console prompt perform the foll...

Page 32: ...32 Chapter 2 Installation Process 320846 A ...

Page 33: ...specifications 35 Table 8 Hardware specifications Characteristic Measurement Form Factor 1U high custom base chassis Dimensions H x W xD 1 72 inches 44 millimeters x 16 9 inches 429 millimeters x 22 inches 559 millimeters Weight approximately 25 pounds Rack mountable rack mount hardware to allow mounting in 19 inch standard rack Bezel plastic front bezel with Nortel name logo and Nortel SNAS 4050 ...

Page 34: ...ATA133 System management CPU temperature voltage monitoring fan monitoring Light emitting diodes LED power green disk drive activity green System status amber includes the following CPU fans 1 4 System fans 5V 12V CPU temperature Motherboard ambient temperature Power supply 300W 100 240VAC 50 60Hz Power consumption 125W typical BTU 429 BTU hour average Mean Time Between Failures MTBF greater than ...

Page 35: ...cations Table 12 lists safety specifications Table 13 lists emissions specifications Table 14 lists certification marks Table 10 Console port setup parameters Parameter Value Baud Rate 9600 Data Bits 8 Parity None Stop Bits 1 Flow Control None Table 11 LAN connection speeds LAN connection speed Connector Medium 10Base T RJ 45 Cat 3 4 or 5 UTP 100Base TX RJ 45 Cat 5 UTP 1000Base T RJ 45 Cat 5 UTP T...

Page 36: ...S 003 Class A Canada AS NZ 3548 Australia New Zealand standard replaced by EN55022 EN55022 emissions EN55024 immunity Europe CISPR 22 Europe VCCI Japan Table 14 Certification marks Compliance Country cULus USA Canada CE Europe Gost Russia NOM Mexico S Mark Argentina TUV GS Germany Europe MIC Korea Table 12 Safety specifications continued Compliance Country ...

Page 37: ...Appendix A Specifications 37 Nortel Secure Network Access Switch 4050 Installation Guide ...

Page 38: ...38 Appendix A Specifications 320846 A ...

Page 39: ...en In diesem Fall muß der Benutzer die erforderlichen Maßnahmen zur Beseitigung ergreifen Attention Ce périphérique est un produit de classe A Il peut provoquer des interférences radio dans un environnement domestique si tel est le cas l utilisateur devra prendre les mesures qui s imposent Precaución Este dispositivo es un producto de Clase A En un entorno doméstico este dispositivo puede ocasiona...

Page 40: ...40 Appendix B Safety Message Translations 320846 A ...

Page 41: ...hrerer Einheiten geeignet Attention si vous installez le module dans une baie ne l empilez pas directement sur un autre Chaque module doit être fixé à sa propre baie à l aide des supports de montage appropriés Ces supports ne sont pas conçus pour résister à plusieurs modules Precaución Cuando monte este dispositivo en un bastidor no apile las unidades directamente una encima de otra Cada unidad de...

Page 42: ...42 Appendix B Safety Message Translations 320846 A ...

Page 43: ...s cordons d alimentation équipés de trajet de mise à la terre Sans mise à la terre adaptée vous risquez de recevoir une décharge électrique en touchant le commutateur Par ailleurs l absence de trajet de mise à la terre peut générer des émissions excessives Peligro Utilice únicamente cables de alimentación con toma de tierra De lo contrario al tocar el interruptor puede recibir una descarga eléctri...

Page 44: ...44 Appendix B Safety Message Translations 320846 A ...

Page 45: ... panel ports 1 and 2 table 22 ports 3 and 4 table 22 P pinouts for DB 9 console connector table 29 port speed and status 1 and 2 table 22 3 and 4 table 22 power connecting 28 disconnecting 28 supplying to switch 28 power button 18 power cords 17 problems troubleshooting installation 31 product support 12 R rack installation 27 rear panel features description 21 S safety electrical 26 mechanical 26...

Page 46: ...A hardware 33 LAN connection speeds 35 power supply 34 safety 35 support Nortel 12 system power LED 18 T technical support 12 terminal access setup 28 text conventions 10 troubleshooting no display text 31 no power 31 ...

Reviews: