Nortel Switched Firewall 2.3.3 User’s Guide and Command Reference
220
Applications
213455-L, October 2005
3.
Specify the SNMP host for the UPS device.
4.
Specify the SNMP port for the UPS device.
5.
Specify the SNMP community string of the UPS device.
6.
Specify the battery level (0—100%) of the UPS device at which the firewall will be shut
down.
7.
Enable UPS Monitor.
Displaying UPS configuration
Verify UPS configuration with the following command:
>> #
/cfg/sys/ups/snmphost
Current value: 0.0.0.0
Enter IP address of the UPS:
(Set IP address of SNMP UPS)
>> #
/cfg/sys/ups/snmpport
Current value: 161
Enter SNMP port:
(Set port used by SNMP UPS)
>> #
/cfg/sys/ups/snmpcomm
Current value: none
Enter SNMP community string:
(Set community string of the UPS)
>> #
/cfg/sys/ups/level
Current value:5
Enter battery level (%)
:
(Specify the battery level)
>> #
/cfg/sys/ups/ena
(Enables APC UPS monitor)
>> #
/info/ups
(Displaying APC UPS status)