/cfg/sys/ups
APC UPS Menu
The APC UPS Menu allows you to configure UPS support on the Switched Firewall. The
items in this menu allow you to specify the communication type used to contact the UPS from
the Switched Firewall.
[APC UPS Menu]
type - Set UPS type
snmphost - Set IP address of SNMP UPS
snmpport - Set port used by SNMP UPS
snmpcomm - Set SNMP community string of the UPS
level - Set battery level (%) at which director shuts down
master - Set UPS Master IP address
ena - Enable APC UPS Monitor
dis - Disable APC UPS Monitor
Table 53
APC UPS Menu (/cfg/sys/ups)
Command Syntax and Usage
type
usb|snmp
This command lets you set the type of UPS communication type used to configure the
UPS support in the Cluster. Select “USB” type when the Switched Firewall has been
connected to the UPS through an USB cable. Select SNMP when the UPS is communi-
cating with the Switched Firewall using the ethernet connection via SNMP.
snmphost
<IP address>
This command lets you specify the IP address of the UPS system. This command is used
when the UPS type is configured to communicate with the firewall via SNMP.
snmpport
<port #>
This command lets you specify the port number on which the UPS snmp listens on. The
default value is the standard snmp protocol number, 161.
snmpcomm
<community string>
This command sets the snmp community name used for communicating with the UPS
system.
level
<0 to 100%>
This command lets you specify the battery level for the UPS. When the UPS is running
on batteries, this value is used as a minimum threshold value. If the battery level runs
below this value, it shuts down the firewalls connected to it. The default value is 5%.