54
Chapter 2 Installation
312755-G Rev 00
To connect the DC input feeds to the BIP:
1
Locate the DC power source for the DC input feed.
2
Determine the power requirements for your configuration (see
Figure 35 on
page 53
).
3
Locate the A and B -48 VDC input feeds (
Figure 36
).
The -48 VDC input feed cables should be tagged with source labels (for
example, -48 VDC Input feed or -48 VDC Return). If they are not labeled, and
you are not sure of the source, ask for assistance from a qualified electrician.
Figure 36
Locating the A and B -48 VDC input feeds
Warning:
Ensure that the DC power source is off or disconnected on the
remote end before you perform any of the steps in this section. You may
need to switch a circuit breaker off or turn off power at the DC input
source.
Note:
Figure 36
shows an example of a site DC input conduit. Your DC
input conduit can look different or can be in a different location than the
one shown in the following examples.
10401EA
-48 VDC Feeds
Return A feed 1
-48VDC A feed 1
Return A feed 2
-48VDC A feed 2
Return B feed 2
-48VDC B feed 2
Return B feed 1
-48VDC B feed 1