Chapter 4 Replacing a PrPMC
59
Installing the 8660 Service Delivery Module (SDM)
Installing a PrPMC
Remove the filler panel from the firewall iSD mini-slot, if necessary, before
beginning this procedure. See
“Removing a PrPMC filler panel” on page 66
1
Place the 8660 SDM
on an antistatic bag, or set it on an antistatic mat.
2
Hold the PrPMC with the components facing up (see
).
Figure 37
PrPMC with components facing up.
3
Place the PrPMC on an empty slot on the 8660 SDM.
Note:
Nortel
recommends that you remove the disk drive (if present)
located behind the PrPMC that you are installing before beginning this
procedure. See
“Removing a disk drive” on page 45
Note:
Ensure that iSDs are installed from right to left (that is, for a
FW1, the iSD is in slot 4 of the SDM FW1 tray; for a FW2, the iSDs are
installed in slots 3 and 4, and so on).