124
Equipment installation and configuration
Execute the
D C D
command for the distant site and compare the
configuration settings at the local and the remote sites. If able to obtain
the distant configuration report and they are both configured correctly, the
MicroLink is up and the communication is established.
To also verify that the communication is established, display the status
at each end of the carrier by executing the
D S
and
D S D
commands
on the MMI terminal. If MicroLink is up (carrier is good end-to-end), the
communication across the link is established.
To display local carrier status:
CRI::
> D S
Display carrier status
CRI Remote IPE S/W L1105-A4 Software Version 1.00 8/11/95 10:45
Local Site
Status at the local site
In Alarm Status: NO
No alarms detected
All Link Maps Normal
No link has been spared
Link 0 Alarm Level 0
Carrier 0 status
Link 1 Alarm Level 0
Carrier 1 status
Link 2 Alarm Level 0
Carrier 2 status
To display remote carrier status:
CRI::> D S D
Display distant carrier status
Distant End Ready
Distant end acknowledged
D S
Command received
CRI Remote IPE S/W R1105-B6 Software Version 1.00 8/11/95 10:45
Remote Site
Status at the remote site
In Alarm Status: NO
No alarms detected
All Link Maps Normal
No link has been spared
Link 0 Alarm Level 0
Carrier 0 status
Link 1 Alarm Level 0
Carrier 1 status
Link 2 Alarm Level 0
Carrier 2 status
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01
4 June 2010