14
Carrier Remote IPE product description
Table 2
Local site carrier hardware list (cont’d.)
Component
Description
NT7R67DA Local
External Maint. Cable
Assy
Cable with the P1 DB-9 male connector that plugs into the NT7R58AA
Maintenance Panel DB-9 female connector, the P3 DB-9 male connector
that plugs into the MMI terminal or modem cable (or the preceding Local
Carrier Interface connection in a daisy-chain), and the P2 DB-9 female
connector that plugs into the SDI port (or the following Local Carrier
Interface connection in the daisy-chain). Refer to Appendix C,
"Single LCI connection diagram (local site connections)" (page 198)
and
Figure 27 "Multiple LCIs connection diagram (local site daisy-chain
connection)" (page 199)
NT7R67EA Coaxial
Interface Adapter
Cable
Cable with one 8-pin modular plug that plugs into the NT7R57AA Carrier
Panel Assy 8-pin modular jack and two BNC connectors that plug into the
carrier link BNC connectors.
NT7R87AA T1 CSU
Cable Kit
This cable kit consists of a DB-15M/RJ-48 adapters and a 9.75 m (32
ft) RJ-48 to RJ-48 cable. The appropriate adapter is used to connect to
a CSU and the cable is used to connect the adapter to the NT7R57AA
Carrier Panel Assy RJ-48 connector.
NT8D46AL System
Monitor Serial Link
Cable
Connects the 6-pin modular jack J5 on the NT7R58AA Maintenance
Panel assembly to the system monitor jack J6 in the pedestal.
NT8D93AJ XSDI I/O
to DTE or DCE Cable
This is a DB-9 male to DB-25 male 4.8 m 16-foot cable used to connect
the SDI Paddleboard to the NT7R67DA Local External Maintenance
Cable P2 DB-9 female connector. The entire NT7R66AA SDI Cable Kit
must also be used.
NT5D40AA Hybrid kit
Used to replace BTUs in some network modules. The replacement is
necessary to be able to install the Local Carrier Interface card in that slot.
Table 3 "Remote Carrier IPE module hardware list" (page 14)
lists the
hardware required for the Carrier Remote IPE UEM column at the remote
site.
“Connection diagrams and external connectors pin assignment” (page
provides external connectors pin assignments.
Table 3
Remote Carrier IPE module hardware list
Component
Description
NT7R52 Remote
Carrier Interface card
Remote Carrier Interface card (installed in the Remote IPE module or
the Remote IPE cabinet).
NT8D37 IPE Module
Carrier Remote IPE module.
NT7R66BA MMI Cable
This is a (32 ft) DB-9 female to DB-25 male cable. Connect the MMI
terminal to the DB-9 male MMI connector on the NT7R61AA Maintenance
Panel Assy.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.