Carrier Remote IPE fault isolation and correction
175
Checking Carrier Remote IPE status using MMI commands
Procedure 42 “Checking Carrier Remote IPE status using MMI commands”
(page 175)
uses MMI commands to maintain Carrier Remote IPE cards
and carrier status.
In the MMI mode, the terminal issues direct commands to the system to
display operational conditions, to set up carrier parameters, and to test
individual carrier links.
To obtain the Local and Remote Carrier Interface card status, follow the
steps in
Procedure 42 “Checking Carrier Remote IPE status using MMI
.
Procedure 42
Checking Carrier Remote IPE status using MMI commands
Step
Action
1
Log in on the MMI maintenance terminal:
CRI::
>L
Login command
Enter Password >
M1LINK
Type in the password.
2
Type
D S
to display near-end carrier status.
Type
D S D
to display far-end carrier status.
The response is displayed on the screen and shows: the
firmware version, present time and date, individual carrier fault
threshold parameters, and the present status of each carrier link.
Example:
CRI::>D S
CRI Remote IPE S/N Software Version x.xx mm/dd/yy
hh:mm
Remote Site
In Alarm State: NO (carriers are not in the alarm state)
All Link Maps Normal
Link 0 Alarm Level 0
Link 1 Alarm Level 0
Link 2 Alarm Level 0
If carrier links mismatch exists, the status displays unequal alarm
levels across a mismatched link. To verify that carrier links are
connected correctly at both ends perform the tests in
carrier link connections at the remote site” (page 128)
in the
Installation section.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.
Summary of Contents for Communication Server 100
Page 213: ......