System messages
Table 31 "System error messages related to the CRI" (page 187)
lists
CRI-related system messages displayed or printed on the system and MMI
terminal or TTY.
Note:
CRInnnn messages are suppressed for a given superloop
if alarms are disabled by the MMI command A D (Alarm Disable).
CRInnnn messages are suppressed for a given carrier link if it is
UNEQUIPPED by the MMI command S C (Set Configuration).
Table 32 "Remote Carrier Interface HEX error codes for self-test" (page
190)
lists HEX codes displayed by the alphanumeric display on the
Remote Carrier Interface card faceplate.
Table 31
System error messages related to the CRI
Error Code
Message description
BSD805/806
Superloop timeslot not available. Check the timeslot allocation for each T1/E1
carrier.
NPR0019
LCI did not respond to the request of disable/enable the RTE superloop.
Ensure that the LCI is installed and that the ENL/DIS switch is in ENL position.
NWS0019
LCI did not respond to the request of disable/enable the superloop. Ensure
that the LCI is installed and that the ENL/DIS switch is in ENL position.
PWRxxxx
Carrier Remote IPE cabinet system monitor emulation.
SCH6575
REM_IPE package is not equipped.
SCH6576
Missing LCI software from disk.
SCH6577
Cannot change SUPT in the defined superloop. Superloop is not disabled.
CRIabcd
Where a=1 for local and 2 for remote, 3 for external, b= carrier 0, 1, or 2,
c= alarm lever 1, 2, or 3, and d= 0 for bit error, 1 for frame slip, 2 for loss of
signal, 3 for blue alarm, 4 for out-of-frame, 5 for within threshold, and 6 for
MMI enabled. That is, carrier equipped using MMI configuration commands.
This is shown in subsequent system error messages.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01