62
Equipment installation and configuration
the NT7R58AA Maintenance Panel Assembly into the connector cutout
J16.
•
Right I/O Panel:
For the second Local Carrier Interface card, install the NT7R57AA
Carrier Panel Assembly into the I/O panel connector cutout J2 and the
NT7R58AA Maintenance Panel Assembly into the connector cutout J1.
Carrier Remote IPE connection record label
Affix the connection record label (
Figure 8 "Carrier Remote IPE Connection
) at the rear of the module housing the Local
Carrier Interface card(s). Place the label at the same level as the
corresponding I/O panel connector cutouts used to install its Carrier and
Maintenance Panel Assemblies for that specific Local Carrier Interface
card. If the label is not available, make a label and paste it on the module.
Figure 8
Carrier Remote IPE Connection Record label
Label entries description:
Remote Site – Name of the Remote Carrier IPE site associated with this
Local Carrier Interface card superloop number (SUPC)
Local Carrier Interface Superloop (SUPC) – Enter here the designated
superloop number for this specific Local Carrier Interface card.
Carrier I/O Panel Connector Position – Enter the number of the selected
connector cutout on the I/O panel where the Carrier Panel Assembly is
installed, for example J22.
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.