76
Equipment installation and configuration
Procedure 7
Connecting a Local Carrier Interface card to the SDI card
Step
Action
1
To connect a single NT7R51 Local Carrier Interface card to the
QPC 841 or other SDI cards:
•
Route the DB-9 female P2 connector of the NT7R67DA cable
assembly to an available SDI port on an SDI card.
•
Plug the DB-9 male connector of the NT8D93AJ XSDI I/O
cable into the DB-9 female SDI connector on the I/O panel.
•
Plug the DB-25 male connector of the NT8D93AJ XSDI I/O
cable into the DB-25 female connector on the NT7R66AA SDI
Cable Kit.
•
Plug the DB-9 male connector of the NT7R66AA SDI Cable
Kit into the DB-9 female connector into the NT7R67DA cable
P2 connector.
2
To connect other SDI cards:
•
Route and install the DB-9 female P2 connector of the
NT7R67DA cable assembly to an available SDI port on an
SDI card.
•
Plug the DB-25 male connector of the NT7R66AA SDI Cable
Kit to connect the DB-25 female SDI connector at the I/O
panel. (The DB-25F/DB-25F adapter is not used).
•
Plug the DB-9 male connector on the NT7R66AA SDI Cable
Kit into the P2 connector on the NT7R67DA cable.
3
To test the MMI and Host SDI login, refer to
and
for login instructions.
Note: For additional information about types of SDI cards,
their SDI ports, and special cables required to connect these
ports, refer to Circuit Card Reference (NN43001-311) ().
--End--
Connecting multiple Local Carrier Interface cards to the MMI
terminal
Make sure that all the NT7R51 Local Carrier Interface cards are properly
configured for the daisy-chain card addressing as shown in
Carrier Interface card DIP-switch positions and function" (page 67) Figure
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01
4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
.
Summary of Contents for Communication Server 100