7-6
Enhanced Receive Multicoupler (ERMC) tests
411-2051-500
Draft
00.01
November 1999
Note: If an imbalance exists, call Nortel Networks RF Engineering
Support for assistance in re-balancing the ERMC output.
Always ensure that the site is balanced for the worst case. The radio TX path
must be equal to or stronger than the Talk-In path. If there are significant
differences in the Talk-out (base TX) levels on different antennas, check for a
defective RF component such as an antenna, a cable, or a combiner.
7
Monitor and record 20 RSSI measurements
simultaneously at both the mobile and the
test TRU. The mobile should be driven
through a predetermined path to repeat the
test for other channels available.
Record and average the levels in the chart.
- End -
Step
Action
Observation