Performing tests using the DCSM in the directed mode
9-7
Wireless Solutions
DualMode 800 Enclosure
Maintenance Manual
MTX08
Round Robin Monitoring
The MON command is executed from the CTU level of the MAP position
with a posted INSV DCCH or ACCH.
The MON command forces the DCSM to scan specific CCHs as specified in
the command options.The MON command sequence is as per Procedure 9-5.
Procedure 9-5
Round Robin Monitoring
Step
Action
Observation
1
Make sure that the DCCH or ACCH and the DCSM have been
posted and are in the INSV state as per the Control Channel Test
Setup Procedure.
2
If the DCSM is in a sectored configuration, force the DCSM to scan
the DCCH of the sector that is to be tested by entering:
>
MON ON <x, y, z, u, v, or w>, <A,D,BOTH>
(Sector Designation), (ACCH, DCCH, or Both)
A = monitor ACCH
only
D = monitor DCCH
only
Both = monitor both
CCH types
3
Example: MTX120 JUL04 12:12:30 1123 INFO Terminal
Maintenance Event
CELL 15 CTU 0 PRTN: Y
EVENT: Unsol Wrong CCH
REASON: CCH Number Wrong
Summary of Contents for DualMode 800
Page 2: ......
Page 4: ......
Page 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Page 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Page 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Page 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Page 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Page 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Page 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Page 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Page 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Page 215: ......