1-4
Equipment operation
Nortel Networks Confidential
411-2051-500
Draft
00.01
November 1999
3. On the second line, press the right arrow key to move the cursor to the
Enable Single option. The options on the third line will change
accordingly as the cursor moves.
4. Press the down arrow key to move the cursor to the third line. The cursor
will highlight the first option on the third line.
5. On the third line, type in the number of the alarm input point that needs to
be enabled. Press the Return key.
Note: For options that have more than one parameter on the third line, use
the left and right arrow keys to move the cursor from one parameter to
another parameter.
6. Press the Return key a second time to execute the selected parameter of
the option. The display will show:
Command Sent...Acknowledge Received
7. Press the up arrow key to move the cursor back to the previous line.
Note: The ‘Monitor’, ‘Show Function Codes’ and ‘Firmware Info’
options do not have a third line on the menu. When selecting these
options, press the Return key after they are selected. The information for
these options will appear on the display.
Input option
You can select the following five functions under the Input option:
•
Monitor
•
Enable Single
•
Disable Single
•
Enable Range
•
Disable Range
Monitor
This function monitors the status of each alarm input point. Figure 1-3 shows
a typical screen display of the Input Monitor option.
Summary of Contents for DualMode 800
Page 2: ......
Page 4: ......
Page 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Page 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Page 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Page 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Page 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Page 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Page 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Page 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Page 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Page 215: ......