11-50
DRU tests
411-2051-500
Draft
00.01
November 1999
7
On the test equipment, enter the channel
number that is to be tested.
For the IFR1600:
(i) use the Data Entry Keys to input the
channel
(ii) press the green ‘ENTER’ key to enter the
input.
8
On the terminal, type:
>set pers ttc
Personality configuration was successful.
The personality of the TRU changes to a
TDMA Traffic Channel.
9
Type:
>set channel xxxx
“xxxx” is the channel number of the TRU
under test.
Channel change was successful.
The channel of the TRU changes to the
desired number.
10
Type:
>set txpowidx 0
PA power change was successful.
The power index of the TRU changes to 0.
11
Type:
>set maxtxpow 15
Set Max power (input value and
value used): 15.0 15.0
PA Max Power (dBm): 15.0
The output power of the TRU changes to
27.0 dBm.
12
Type:
>run inject to dsp 1 52 b6 0 0
1
13
Type:
>set pa on
Status change was successful.
The TRU transmitter is turned on.
- continued -
Step
Action
Observation
Summary of Contents for DualMode 800
Page 2: ......
Page 4: ......
Page 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Page 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Page 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Page 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Page 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Page 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Page 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Page 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Page 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Page 215: ......