B-4
Appendix B: Test forms
411-2051-500
Draft
00.01
November 1999
DRU checks — Transmit tests (Chapter 11)
Cell:
Date:
Performed by:
RF Frame:
TRU Shelf:
TRU transmit tests
TRU 1
TRU 2
TRU 3
TRU 4
TRU 5
TRU 6
TRU 7
TRU 8
Serial number:
Channel number:
TX frequency (MHz):
EEPROM CRC check:
TX carrier frequency error:
-220 to +220 Hz
Wideband modulation:
Deviation 7.2 to 8.8 kHz
SAT at 5970 Hz:
Frequency 5965 to 5975 Hz
Deviation 1.8 to 2.2 kHz
SAT at 6000 Hz:
Frequency 5995 to 6005 Hz
Deviation 1.8 to 2.2 kHz
SAT at 6030 Hz:
Frequency 6025 to 6035 Hz
Deviation 1.8 to 2.2 kHz
Residual modulation:
Deviation -0.5 to +0.5 kHz
Transmit audio level:
Deviation 2.61 to 3.19 kHz
Modulation limiting:
Deviation less than 12 kHz
1 kHz tone generation test:
Frequency 999 to 1001 Hz
Deviation 7.2 to 8.8 kHz
Transmit carrier power measured at antenna port of duplexer
Per channel power level:
Within site specifications
Summary of Contents for DualMode 800
Page 2: ......
Page 4: ......
Page 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Page 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Page 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Page 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Page 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Page 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Page 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Page 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Page 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Page 215: ......