DualMode 800 Enclosure Every Visit Checklist
2-13
Wireless Solutions
DualMode 800 Enclosure
Maintenance Manual
MTX08
DualMode 800 Enclosure Every Visit Checklist
Date:
____________________________
Performed by:
___________________________
Equipmene bays
1
Check all breakers for correct position, that is, ON/OFF on all power equipment
2
Check fuse indicators; replace fuses if necessary
3
Check receive multicoupler fuse
4
Verify that all cooling fans are working in each bay
Enclosure and site
5
Check that no high or low temperature alarm is present
6
Check that the interior lights work
7
Verify automated security system by tripping alarm (reset after test)
8
Check air filters on air exchange/conditioner equipment
9
Verify the presence of a fire extinguisher & check expiry date
10
Check for leaks in the shields
11
Check the condition around the enclosure
12
Check for deterioration of paint on walls
13
Check cable access ways through the walls for deterioration
14
Inspect grounding system
15
Perform general housekeeping duties to remove dust, dirt and trash
16
Complete manuals, site logs, and records
17
Turn tower lights on and verify that all lights are working
18
Inspect antenna ground for corrosion
19
Security checks on fences, windows, doors, tower guy anchors
20
Check that site gate locks are secure
21
Clean up any debris around the site area
22
Check that there are no overhead lines down
Pressurized transmission lines to antenna
23
Check the nitrogen tank pressure, manifold, and the dehydrator
Summary of Contents for DualMode 800
Page 2: ......
Page 4: ......
Page 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Page 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Page 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Page 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Page 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Page 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Page 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Page 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Page 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Page 215: ......