26
Symposium Express Call Center
Media Card
Standard 2.0
Upgrading the Media Card
Introduction
Check the version number of the firmware and loadware on the Media Card to
ensure that they are the latest available version. (The
Symposium Express Call
Center Distributor Technical Reference
contains the latest firmware versions.)
To determine the firmware version
1
Establish a serial connection to the Media Card, using either the mini-DIN
connector on the faceplate or the backplane connector.
For more information, see “Cabling the Media Card” on page 18. For
information on the serial connection, see the
Voice Services on Media Card
Maintenance and Troubleshooting Guide
.
2
Restart the card by pressing Reset on the faceplate.
Result:
The version numbers of the card firmware appear. The following is
an example of a startup sequence:
Rebooting Pack ...
value = 0 = 0x0
->
MC Firmware Rls 6.5
8051XA Firmware Version 4.9 6 Dec 2002
(C) Nortel Inc. 2001
EPLD Version: 4.0
32K External RAM detected
8K DPRAM detected
Dongle serial number: 10081198
All FPGAs are configured
All self tests have passed
SRAM test okay
SDRAM Addr test okay
SDRAM blank over
Early serial debug initialized
VxWorks System Boot
Copyright 1984-1998 Wind River Systems, Inc.