70
Media Application Server platform
Power
This section outlines the power requirements for each of the Media
Application Server platforms:
•
"IBM xSeries 3550 power requirements" (page 70)
•
"IBM xSeries 336 power requirements" (page 71)
•
"IBM xSeries 335 power requirements" (page 71)
•
"IBM eServer BladeCenter power requirements" (page 72)
•
"IBM eServer BladeCenter T power requirements" (page 72)
IBM xSeries 3550 power requirements
Table 16 "IBM x Series 3550 power requirements" (page 70)
lists the power,
heat, and cooling specifications that apply to this platform.
Table 16
IBM xSeries 3550 power requirements
Specification
Values
Input voltage
Low range: minimum 100 V ac,
maximum 127 V ac
High range: minimum 200 V ac,
maximum 240 V ac
Power supply
Maximum of two redundant 670
watt (110 or 220 V ac auto-sensing)
hot-swappable power supplies.
Heat emissions
Minimum configuration: 662 BTU per
hour (194 watts)
Maximum configuration: 2390 Btu per
hour (700 watts)
Sound emissions
Idling: 6.8 bels maximum
Operating: 6.8 bels maximum
Cooling system
Hot-swappable fans
Standard: five
Maximum: six (with two
microprocessors installed)
Nortel Media Application Server
Media Application Server Planning and Engineering
NN42020-201
01.04
Standard
4.0
27 July 2007
Copyright © 2007, Nortel Networks
.