Chapter 25 — Fault locating and clearing
Page 535 of 536
Option 11C Compact
Planning, Installation, Fault Clearing and CCBR Guide
8
If there was a sysload (SYSLOAD) while you were clearing a fault,
reset the correct time and date by entering
LD 2
STAD (day) (month) (year) (hour) (minute) (second)
Check the time and date you entered
TTAD
End the session in LD 2 and log out of the system
****
LOGO
9
Replace any covers that were removed.
10
Tag defective equipment with a description of the fault and return it to
a repair center.
—————————— End of Procedure ——————————