Chapter 20 — Meridian Mail Compact Option installation and maintenance
Page 197 of 536
Option 11C Compact
Planning, Installation, Fault Clearing and CCBR Guide
If you are installing a new Meridian Mail system, install the RSM Assembly
Module before you install the Meridian Mail Compact Option CPU card
assembly.
To install the RSM Assembly Module, follow these steps:
1
Mount the RSM Assembly Module on the same wall as the Option 11C
Compact cabinet, with the hardware provided. Ensure that the RSM
Assembly Module is mounted close enough to the cabinet to make the
cable connections decribed below.
2
At the bottom right of the Option 11C Compact backplane, loosen the
velcro fastener attached to the 25-pin connector labelled P14. Insert
one end of the supplied four-foot RSM cable (NTMW51AA) into P14,
and tighten the velcro fastener.
3
On the RSM Assembly Module, loosen the velcro fastener attached to
the 25-pin connector labelled P1. Insert the other end of the RSM
cable from the Option 11C Compact backplane into P1, and tighten the
velcro fastener.
4
Move the small switch on the RSM Assembly Module to the “Normal”
position as indicated on the assembly.
You can now install the Meridian Mail Compact Option CPU card assembly.
You can connect cables to the RSM Assembly Module while the module is
connected to the
Option 11C Compact backplane
and while Meridian Mail is
on. For information on connecting peripheral devices to the
RSM Assembly
Module
“Installing Hospitality voice system hardware” on page 202
.
Installing the hard drive
The following procedure describes installation of a new hard drive onto the
CPU card in a new system. If you need to replace a hard drive see
.
Summary of Contents for Meridian Meridian 1
Page 3: ...553 3121 210 Standard 3 0 January 1999 ...
Page 17: ...xiv Contents 553 3121 210 Standard 3 0 January 1999 ...
Page 97: ...Page 78 of 536 Chapter 8 Installing a new system 553 3121 210 Standard 3 0 January 1999 ...
Page 107: ...Page 88 of 536 Chapter 10 Installing the system ground 553 3121 210 Standard 3 0 January 1999 ...
Page 113: ...Page 94 of 536 Chapter 11 Installing the power supply 553 3121 210 Standard 3 0 January 1999 ...
Page 125: ...Page 106 of 536 Chapter 12 Adding an expansion cabinet 553 3121 210 Standard 3 0 January 1999 ...
Page 209: ...Page 190 of 536 Chapter 18 Connecting the trunks 553 3121 210 Standard 3 0 January 1999 ...
Page 323: ...Page 304 of 536 Chapter 21 Installing Hospitality 553 3121 210 Standard 3 0 January 1999 ...
Page 419: ...Page 400 of 536 Chapter 23 Pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Page 555: ...Page 536 of 536 Chapter 25 Fault locating and clearing 553 3121 210 Standard 3 0 January 1999 ...