MCRM-S card replacement procedures
286
Meridian SL-100 SE Commercial Systems Card Replacement Procedures MSL15
NTMX77
in an MCRM-S RCC2
(continued)
Replacing an NTMX77 in an MCRM-S RCC2
At your current location
1
Proceed only if you have been directed to this card replacement
procedure from a step in a maintenance procedure, are using
the procedure for verifying or accepting cards, or have been
directed to this procedure by your maintenance support group.
2
Obtain a replacement card. Ensure that the replacement card
has the same product engineering code (PEC), including suffix,
as the card to be removed.
At the MAP terminal
3
Set the MAP terminal to the peripheral module (PM) level and
post the RCC2 by typing the following string:
> MAPCI;MTC;PM;POST RCC2 rcc2_no
and pressing the Enter key.
where
rcc2_no
is the number of the RCC2 to be posted
Example of a MAP response
CAUTION
Loss of service
When replacing a card in the RCC2, ensure
that the unit in which you are replacing the
card is inactive and that the mate unit is
active.
Summary of Contents for Meridian SL-100 SE
Page 2: ......
Page 4: ......
Page 6: ...vi Publication history 555 4031 547 Standard 12 02 July 2002...
Page 10: ...x Contents 555 4031 547 Standard 12 02 July 2002...
Page 46: ...46 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 56: ...56 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 72: ...72 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 80: ...80 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 96: ...96 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 108: ...108 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 120: ...120 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 138: ...138 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 149: ...149 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 150: ...150 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 160: ...160 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 187: ...187 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 188: ...188 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 198: ...198 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 208: ...208 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 218: ...218 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 228: ...228 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 252: ...252 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 294: ...294 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 320: ...320 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 322: ...322 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 337: ......