MCRM-S card replacement procedures
335
Meridian SL-100 SE Commercial Systems Card Replacement Procedures MSL15
NTMX87
in an MCRM-S EXT or RCC2 shelf
(continued)
23
Use the following information to determine where to proceed.
24
Post the inactive RCC2 in which the NTMX87 card is located by
typing the following string:
> post rcc2 rcc2_no
and pressing the Enter key.
where
rcc2_unit_no
is the number of the RCC2 unit associated with the faulty
card
25
Return the inactive RCC2 unit to service by typing the following
string:
> RTS UNIT rcc2_unit_no
and pressing the Enter key.
where
rcc2_unit_no
is the number of the RCC2 unit posted in Step 24.
26
Use the following information to determine where to proceed.
27
Test the RCC2 by typing the following string:
> TST UNIT rcc2_unit_no
and pressing the Enter key.
where
If RTS
Do
for C-side links passed
Step 24
for C-side links failed
Step 32
for P-side links passed
Step 33
for P-side links failed
Step 32
If RTS
Do
passed
Step 27
failed
Step 32
Summary of Contents for Meridian SL-100 SE
Page 2: ......
Page 4: ......
Page 6: ...vi Publication history 555 4031 547 Standard 12 02 July 2002...
Page 10: ...x Contents 555 4031 547 Standard 12 02 July 2002...
Page 46: ...46 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 56: ...56 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 72: ...72 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 80: ...80 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 96: ...96 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 108: ...108 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 120: ...120 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 138: ...138 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 149: ...149 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 150: ...150 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 160: ...160 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 187: ...187 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 188: ...188 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 198: ...198 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 208: ...208 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 218: ...218 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 228: ...228 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 252: ...252 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 294: ...294 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 320: ...320 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 322: ...322 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 337: ......