1-360 Trouble locating and clearing procedures (continued)
297-8021-544 Standard 14.02 May 2001
Running a C7BERT for high-speed links
(continued)
52
Determine the result of injecting bit errors.
Note: In the example in step 51, the number of bit errors received appears
to the right of Rx Bit Errors.
53
Subtract the result of the HSL C7BERT recorded in step 49 from the result
obtained in step 51. This action checks for correct bit error rate (BER) circuit
operation.
54
To determine if periodic reports have been requested, type
>REPORT link_no STATUS
and press the Enter key.
where
link_no
is the number of the link (0 to 15) on which the HSL C7BERT is running
55
To clear the previous report interval, type
>REPORT link_no OFF
and press the Enter key.
where
link_no
is the number of the link on which the HSL C7BERT is running
MAP response:
56
To set the number of reports per hour, type
>REPORT link_no ON number
and press the Enter key.
where
If the difference is
Do
1
step 42
anything else
step 78
If the response is
Do
Link nn: Automatic query
reporting active at: mm times
per hour
step 55
Link nn: Automatic query
reporting is not active
step 56
anything else
step 78
Link nn: Automatic query reporting has been terminated