Remote Gateway 9150 Installation and Administration Guide
467
June 2005 Display
log
definitions
Statistic
Definition
LOG NUMBER
65
DESCRIPTION
This log indicates that the unit attempted a PSTN connection to its
peer unit, and that the connection attempt succeeded initially at
56K, failed at 65K, and then failed again at 56K.
SEVERITY
MAJOR
TASK
TP
PRODUCT
RLC, 9150
CANCELLATION
None
ACTION TO BE TAKEN:
This problem is most likely related to log number 64 where a clear
64K channel could not be obtained.
It is possible that the attempt to increase speed to 64K caused a
problem with the central office, making it impossible to re-establish
at 56K. This would increase the likelihood of the problem being due
to a high bit error rate on the link.
PARAMETERS
None
DISPLAYED TEXT
PSTN connection failed to re-initiate at 56K