22
S
ECTION
6
approaching vehicle detected will send a
command to the controller and that phase
will become active. If an approaching
vehicle is detected by another traf
fi
c sensor,
that phase will be put in queue until the
active phase is complete. Once all phases
are complete and no further phases are
in queue, all phases will remain red until a
vehicle is detected.
Rest Green –
When actuation is set to
“Rest Green”, it will remain green following
actuation and expiry of the green time,
while the other phase will remain red until
a vehicle is detected. If an approaching
vehicle is then detected by another traf
fi
c
sensor, that phase will be put in queue until
the active phase has reached the minimum
green time and no vehicles are in queue
or have reached the maximum green time,
regardless of vehicles being in queue. The
phase with the vehicle in queue will become
active and will remain green until a vehicle
is detected by a traf
fi
c sensor assigned to
another phase.
Last Served –
When actuation is set to “Last
Served”, the machine will turn green when
it has been actuated and will remain in this
state until another machine within the same
network is actuated.
Nil (Fixed Time) –
a preset time given to
each movement, every cycle, regardless of
changes in traf
fi
c conditions.
Locking –
Enables the controller to remember
or hold a vehicle call (even after the calling
vehicle leaves the detection area) until satis
fi
ed
by the appropriate green indication.
Yellow Lock –
The controller “remembers”
vehicle actuations that occur during the
yellow and red display of the signal phase.
When the controller determines if the phase
should be called for service, it uses the
remembered actuations to call the phase
to service, even if the detected vehicle has
since left.
Non-Lock –
The controller does not
remember actuations and the phase will
be called to service only if it has a currently
occupied detector area.
Passage Time –
the interval of time that is
added to the minimum green time for each
vehicle actuation, until the maximum green
time is reached.
Force Minimum Recall –
in the absence of a
vehicle call on the phase, a temporary call to
service the minimum initial time will be placed
on the phase. If a vehicle call is received prior
to the phase being serviced, the temporary call
will be removed.
6.2
W
Z
S
FEB/01/17 09:53AM
PROGRAM: MODEL V##
HOME
>
WZ SETUP
BATTERY:
24.0 VOLTS
UNIT:
PRIMARY
RADIO CHANNEL:
03
RADIO SIGNAL:
DEFAULT FLASH RED
PRESS START TO RESUME
UNIT ID
RADIO CHANNEL
PRIMARY
SITE LAYOUT
TIMING
03
ONE-WAY ZONE
Unit ID –
used to designate each unit as either a
primary or secondary machine. Each unit will have
a different designation. Only 1 primary machine is
needed per work zone.
Radio Channel –
there are 10 radio channels and
1 hardwire setting available. Every machine in the
work zone must be on the same radio channel in
order to work together.
Site Layout –
the site layout tab allows the user
to select a prede
fi
ned layout to suit the work
zone. There are 20 layouts to choose from.
Timing –
this selection is a shortcut to the
CHANGE TIMING screen which allows you to set
the signal timing for the signals in the work zone.
This can only be done on the primary controller.