Troubleshooting

feedback@natitools.com

Immediately unplug compressor from
its electrical outlet. Do not operate
compressor until a qualified service
technician can replace pressure
switch.

Replace safety valve

Close drain valve

Replace safety valve

Have a qualified service technician
replace pressure controller

Make sure compressor is plugged into
a working 120V, grounded, electrical
outlet

Replace Fuse

Solution

Defective pressure switch

Pressure switch will not
turn off compressor at 100
PSI

Defective safety valve

Safety valve releasing

Drain valve not fully closed

Air leak in safety valve

Defective pressure controller

Low pressure

Loose Electrical Connections

Blown Fuse

Compressor will not start

Possible Cause

Problem

Summary of Contents for 7517

Page 1: ...operty damage Read and understand all of the warnings and safety instructions provided before using this equipment CAUTION The air compressor should be operated on a dedicated 15 amp circuit If the circuit does not have 15 free amps available a larger circuit must be used Always use more air hose before utilizing extension cords Low voltage could cause damage to the motor Risk of moving parts If t...

Page 2: ... compressor after a leak has been found or tried to make any modifications to the tank Never modify the air compressor s factory settings which control the tank pressure or any other function PARTS AND FEATURES Drain Valve Used to drain condensation from the air tank Located on bottom of tank Motor Thermal Overload The motor has an automatic thermal overload protector If the motor overheats this p...

Page 3: ...lation having an outer surface that is green with or without yellow stripes is the grounding wire Check with a qualified electrician or serviceman if the grounding instructions are not completely understood or if in doubt as to whether the product is properly grounded Do not modify the plug provided if it will not fit the outlet have the proper outlet installed by a qualified electrician ASSEMBLY ...

Page 4: ...om air flow valve 3 Relieve the air tank pressure and remove moisture by opening the tank drain valve Turn the valve slowly counterclockwise until the pressure is relieved Then retighten the drain valve 4 Allow the air compressor to completely cool Then store the unit in a clean dry safe location out of the reach of children INSPECTION MAINTENANCE CLEANING 1 WARNING Make sure the compressor is OFF...

Page 5: ...ed service technician replace pressure controller Make sure compressor is plugged into a working 120V grounded electrical outlet Replace Fuse Solution Defective pressure switch Pressure switch will not turn off compressor at 100 PSI Defective safety valve Safety valve releasing Drain valve not fully closed Air leak in safety valve Defective pressure controller Low pressure Loose Electrical Connect...

Page 6: ...se abuse negligence or accidents repairs or alterations or a lack of maintenance NATI shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To receive service under warranty the original manufacturer part must be returned for examination by an authorized service center Shipping and handling char...

Page 7: ...8807517 08 13 2 GALLON AIR COMPRESSOR For Customer Service please call 1 800 348 5004 or email feedback natitools com 7 MODEL 7517 ...

Page 8: ...ylinder Head 1 47 Handle 1 14 Connector 2 48 Handle Soft Grip 1 15 Silica Gel Ring 31 5 x 1 8 1 49 Cords 1 16 Screw M4 x 40 4 50 Flat Washer 1 17 Flat Washer 5 51 Zip Tie 1 18 Spring Washer 5 52 Rubber Sheath 1 19 Fan 1 53 Air Tank 1 20 Screw M4 x 10 1 54 Drain Valve 1 23 Tube 1 55 Rubber Foot 4 24 Pressure Regulator 1 56 Pressure switch 1 25 Safety Valve 1 57 Ball 1 26 Tank Pressure Gauge 1 58 Sp...

Reviews: