background image

 

8

III.) Pump Preparation 

*Comet Pumps Only

 

A.) Replace shipping oil plug with vented plug. 

 
 
**Cat Pumps Only

 

A.) Remove shipping tape from oil fill cap 
B.) Make sure the oil is 1/2 way up oil sight glass. 

 
 
 
 
 
 

 

Quantities Of Fluid

 

Pump Type 

of 

Fluid 

QTY 

Comet GXD 1617-E 

UTTO* 

5.0oz (0.15L) 

Comet GXD 2527G 

UTTO* 

5.0oz (0.15L) 

Cat 2DX 

SAE 30** 

8.5oz (0.25L) 

Cat 3DX 

SAE 30** 

8.5oz (0.25L) 

*Universal Tractor Transmission Oil or Mobil 1 15W50 
**SAE Non-Detergent (order Cat Pump Oil Item# 22158) 

 

 
 
 
 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 157305

Page 1: ...cts Pump Oil Pump is shipped with oil Change oil plug if and check pump oil level before starting Use UTTO for Comet and Cat Pump oil item 22158 for Cat oil changes Water Make sure your water flow is 20 higher than the pressure washer s flow rate Make sure your water is clean and particle free Storage Do not allow water to freeze in the pump hose coil or spray gun Spraying Chemicals Use any North ...

Page 2: ... run machine without sufficient lubrication or sufficient water to cool the pump 9 Wear safety glasses gloves face protection and appropriate clothing when operating the machine 10 Do not operate this machine with broken or missing parts Never alter the manufacturer s original design or deactivate any safety device on the machine 11 Risk of exposure to dangerous chemicals Wear protective gloves wh...

Page 3: ...otection from the risk of electric shock Should replacement of the plug or cord become necessary use only identical replacement parts that include GFCI protection 2 For a product rated more than 125 volts GROUND FAULT CIRCUIT INTERRUPTER PROTECTION To comply with the National Electric Code NFPA 70 and to provide additional protection from the risk of electric shock this pressure washer should only...

Page 4: ...power 1 5 hp 5 hp 2 0 hp 5 hp Maximum Temperature 250 F 250 F 250 F 250 F Approved Fuels 1 or 2 Diesel Kerosene Fuel Oil 1 or 2 Diesel Kerosene Fuel Oil 1 or 2 Diesel Kerosene Fuel Oil 1 or 2 Diesel Kerosene Fuel Oil Fuel Capacity 8 25 gal 8 25 gal 8 25 gal 8 25 gal Discharge Hose 3 8 x 50 3 8 x 50 3 8 x 50 3 8 x 50 Power Requirements Dedicated NEMA Receptacles 5 20R 6 30R 5 20R 6 30R Volts 115V 2...

Page 5: ...r 2 High Pressure Water Outlet 11 Tee 20 Quick Connector 3 Motor 12 Safety Relief Valve 21 Spray Gun 4 Burner 13 Pump 22 Grip 5 Fuel Fill Cap 14 Gun Hooks 23 Lance Wand 6 Fuel Tank 15 Power Switch 24 Power Cord Hangers 7 Control Box 16 Thermostat 25 High Pressure Hose Hanger 8 Elbow 17 Service Panel 26 Garden Hose Water Inlet 9 Swivel Fitting 18 Nozzles ...

Page 6: ...npack Separate and identify all components Use the assembly instructions in this manual for assembly High Pressure Hose Qty 1 Wheel Retainer Qty 2 Spray Gun Grip Qty 1 Wheel Qty 2 Pressure Washer Qty 1 Fastener Bag Qty 1 Nozzle Qty 6 ...

Page 7: ...ay from frame 3 Slide the two wheel retainers onto the end of the axle Tighten the set screw with a hex wrench Description Qty Wheel 2 Wheel Retainer 2 B 1 Install the pressure hose onto the pressure washer as shown 2 Connect the other end of the pressure hose to the spray gun as shown 3 Make sure all plumbing connections are tight Description Qty Spray Gun Lance 1 Spray Hose 1 Wheel Retainer Whee...

Page 8: ...m oil fill cap B Make sure the oil is 1 2 way up oil sight glass Quantities Of Fluid Pump Type of Fluid QTY Comet GXD 1617 E UTTO 5 0oz 0 15L Comet GXD 2527G UTTO 5 0oz 0 15L Cat 2DX SAE 30 8 5oz 0 25L Cat 3DX SAE 30 8 5oz 0 25L Universal Tractor Transmission Oil or Mobil 1 15W50 SAE Non Detergent order Cat Pump Oil Item 22158 ...

Page 9: ... where exhaust fans may cause an insufficient supply of oxygen Proper combustion can only be obtained when there is a sufficient supply of oxygen available for the amount of fuel being burned If it is necessary to install a unit in a poorly ventilated area outside fresh air may have to be piped to the burner and a fan installed to bring sufficient air into the unit VI Oil Burner Burner Air Adjustm...

Page 10: ...ned for a pressurized water source such as a city water faucet Sucking water out of a tank may cause pump cavitation and damage to your pump However the inlet pressure of the pump must not exceed 115 psi 8 bar E Always use a flexible rubber hose for your water supply Do not use rigid piping F Do not pump flammable liquids or liquids containing incompatible chemicals or solvents III Before Starting...

Page 11: ... turn off IMPORTANT Do not run the machine in hot mode without any fuel in the fuel tank The fuel pump will be damaged if it is run dry To Clean WARNING Wear eye ear hand foot and skin protection at all times while operating this pressure washer DANGER Do not point the spray wand at yourself or at any person Bodily injury may result from water under high pressure CAUTION Be careful on painted or d...

Page 12: ... too close 11 Small parts should be washed in a basket so the pressure does not push them away Larger light weight parts should be clamped down 12 The pressure washer is set to the maximum rated pressure when it leaves the factory To adjust the pressure turn the unloader knob counter clockwise WARNING Do not alter the unloader valve s maximum pressure Excess pressures could cause serious injury an...

Page 13: ...epairs are required North Star Customer Service will assist in these repairs as needed but if an inoperable pressure washer creates a major expense to your business then we strongly recommend the following 1 Have someone on staff who is trained in the operation of the pressure washer and is capable of making minor repairs and performing all preventative maintenance procedures as outlined in the pr...

Page 14: ...ate the pressure washer if the hose is cracked worn or leaking A Check all hoses for leaks B Check all hoses of worn areas Changing The Pump Oil Change oil after first 50 hours then every 3 months or 500 hours 1 Remove oil drain plug on Cat pumps 2 Drain pump oil 3 Replace oil drain plug 4 Fill pump oil according to table below 5 Use dip stick to fill to proper level or sight glass on Cat pumps On...

Page 15: ... the inlet strainer when finished Coil Desooting Poor grades of fuel oil or inadequate combustion air will cause heavy soot build up on the outside surface of the heating coil These deposits will insulate the coil This will restrict the air flow through the coil further aggravating the soot build up Most coils will never require desooting However to desoot a coil 1 Wear protective clothing goggles...

Page 16: ...ame 2 Remove the 4 nuts that attach the burner to the heating chamber You do not have to disconnect the fuel lines or the electric cords 3 Let the burner fall away from the heat exchanger 4 Clean off carbon deposits which may have accumulated on the tips of the electrodes 5 Reset the spacing as shown below 4 Nuts 00793 00794 1 16 1 8 7 16 Electrodes ...

Page 17: ...nstructions to prevent the pump from freezing during storage Winter Storage Items needed 12 piece of garden hose or equivalent funnel and RV antifreeze approximately 2 gallons 1 Attach the garden hose with funnel to the pump inlet see illustration 2 Pour RV antifreeze into the funnel 3 Turn the unit on and make sure the burner is off 4 Let the pump run no more than 15 seconds at a time until antif...

Page 18: ... all connections between pump and gun for leaks Tighten loose components and replace damaged components Gun leaking internally Replace spray gun Smoke From Heat Exchanger Causes Solutions Air band not adjusted properly due to different elevation Adjust the air band until the burner burns cleanly See Oil Burner under Installation Instructions Poor quality fuel Use Kerosene for the cleanest burn Wat...

Page 19: ...19 M157305G 157305 157306 157307 157308 Parts Breakdown ...

Page 20: ... 1 157305 157306 778670 Leeson 5 HP Motor 1 157306 157308 22 36180 Vented Wrap Stainless 1 157307 157308 49 777617 Leeson 2 HP Motor 1 157307 23 38120 Insulation Gasket 1 ALL 50 779303 Control Box Cover 1 ALL 24 778111 Heat Exch Mount Weld 1 ALL 51 31985 Grommet 1 ALL 777166 Burner 120V 1 157305 157307 52 779301 Control Panel Weldment 1 ALL 25 778189 Burner 230V 1 157306 157308 53 35198 Grommet 7 ...

Page 21: ...8 2 35918 Thermal Protector 1 4 1 157307 157308 3 777340 1 4 MPT x 1 4 Hose Barb 1 157308 4 778236 22mm Thread On Coupler 1 157305 5 777410 3 8 Street Elbow 1 157305 157306 38584 3 8 NPT Easy Start Valve 1 157308 6 777837 3 8 Plug 1 157307 7 777411 3 8 Tee 1 157307 157308 8 38596 Inlet Filter 1 157307 157308 9 777165 Braided Chemical Hose 12 157308 ...

Page 22: ...22 ...

Page 23: ...23 ...